Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Fillers Included
- Polymer Name
- Reinforcement Material
- Abbreviation
- PA 6.6 GF 30
- Designation
- Polyamide 6.6 30 % glass fibre
- Type of Polymer
- Thermoplastic
- Trade Name
- CENTROMID 6.6 GF
- Technologies
Features & Benefits
- Materials Features
Applications & Uses
- Applications
- Plastics & Elastomers End Uses
- Field of Use
- Automotive industry
- Electrical industry
- Mechanical engineering
- Medical technology
- Plastics industry
- More industries
- Field of Application
- Distance pieces
- Housing parts
- Threaded bolts
Properties
- Color
- Physical Properties
- Mechanical Properties
- Thermal Properties
- Electrical Properties
Value | Units | Test Method / Conditions | |
Density | 1.34 | g/cm³ | ISO 1183 |
Moisture Pick-up till Saturation (in normal climate 23 °C / 50% r.h.) | 1.7 | % | ISO 62 |
Water Absorption Till Saturation (in water at 23°C) | 5.5 | % | ISO 62 |
Value | Units | Test Method / Conditions | |
Tensile Stress at Break [v = 5 mm/min] | 100.0 | MPa | ISO 527-2 |
Rockwell Hardness (Measured with Test Pieces 10mm Thick) | 76 | Scale M | ISO 2039-2 |
Nominal Percentage Elongation at Break | 5.0 | % | ISO 527-2 |
Tensile Modulus of Elasticity | 5900.0 | MPa | ISO 527-2 |
Ball Indentation Hardness (value at 30 sec.) | 165.0 | MPa | ISO 2039-1 |
Charpy Impact Strength (+23 °C) | min. 50 | kJ/m² | ISO 179/1eU |
Charpy Impact Strength - notched (+23 °C) | 6.0 | kJ/m² | ISO 179/1eA |
Value | Units | Test Method / Conditions | |
Temperature For Usage in Air (short term) | max. 240 | °C | — |
Temperature For usage in Air (lasting) | max. 120 | °C | — |
Minimum Service Temperature in Air | -20.0 | °C | — |
Heat Distortion Temperature (HDT A process) | 150.0 | °C | ISO 75-2 |
Coefficient of Linear Expansion (at length, 23 - 60 °C) | 0.5 | 10-4/K | ISO 11359 |
Thermal Conductivity (+23°C) | 0.3 | W/(K · m) | DIN 52612 |
Flammability According UL Standard (thickness 3 and 6 mm) | HB | Class | UL 94 |
Melting Point (DSC, 10 K/min) | 255.0 | °C | ISO 3146 |
Value | Units | Test Method / Conditions | |
Specific Insulation Resistance | min. 10^12 | Ohm · m | IEC 60093 |
Specific Surface Resistance | min. 10^13 | Ohm | IEC 60093 |
Regulatory & Compliance
- Food Compliance BfR
- No
- Food Compliance FDA
- No
Packaging & Availability
- Tolerance Length
- 0 - 3
- Rods
- 10 - 150
- Stock Lengths
- 1,000 | 3,000