Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- CASE Ingredients Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- CASE Ingredients Features
- Advantages
- VOC free for a healthier environment
- Contributes to LEED® credits
- Manufactured and supplied from Southeast United States
- Lowest life-cycle costing flooring system available
- Extensive color capabilities allow for unlimited design variations
- Self-priming, no primer needed
Applications & Uses
- Markets
- Adhesive & Sealant Type
- Typical Uses
- TERRAZZCO® Terraglow™ is perfect for almost any surface where a uniformly even, highly durable product is desired.
- TERRAZZCO® Terraglow™ provides the best in esthetic value and innovation making it ideal for commercial, industrial, and institutional uses.
- TERRAZZCO® Terraglow™, when integrated with marble or granite aggregate resists heavy industrial wear and chemical corrosion making it perfect for pharmaceutical and chemical plants.
- TERRAZZCO® Terraglow™ is the superior decision for educational institutions, medical centers, sports facilities, and institutions because of its hygienic, smooth surface that is effortless to clean. Also available for safety and special effects applications.
- Application
Surface Preparation: All work should be performed by trained and experienced contractors or maintenance personnel. Concrete surface and air temperature must be a minimum of 55°F during installation and cure. Concrete surface temperature must be 5°F above the dew point to ensure proper curing of the terrazzo floor.
Consult installer for job specific slab conditions for TERRAZZCO® epoxy terrazzo flooring system installation. Concrete surface must be free of dirt, waxes, curing agents, and any other foreign materials. Surfaces should be prepared by grinding or shot blasting and any repairs to concrete must be made prior to applying this product. An active vapor barrier under the concrete must be made prior to applying this product. An active vapor barrier under the concrete slab is required. Concrete slabs receiving resinous terrazzo flooring must be tested for relative humidity according to ASTM F-2170 (Relative Humidity in Concrete Floor Slabs using in situ probes). Measurements must be made using Wagner Electronics Rapid RH® 4.0 Smart Sensor and Rapid RH® Easy Reader. RH reading below 75% do not require the application of a vapor moisture mitigation system. 75% of higher requires the use of Moisture Mitigation System MMS 950. A record sheets should be filled out that includes the ambient temperature and humidity during testing along with the substrate temperature and relative humidity. The test must be conducted at end user environmental conditions. Any deviation from this procedure will result in the warranty being voided.
Materials Needed
- Mineral spirits or isopropyl alcohol for cleaning equipment.
- Mixing equipment appropriate for work site.
Mixing Application
Premix TERRAZZCO® Terraglow™ resin part A before using. Mix five (5) parts of TERRAZZCO® Terraglow™ resin part A with one (1) part of TERRAZZCO® hardener 158 part B by volume with a slow speed drill until liquids are completely blended. Introduce the appropriate amount of aggregate and continue to mix.
Clean Up
Clean skin with soap and water. Tools and equipment should be cleaned with isopropyl alcohol or mineral spirits before the epoxy hardens. Failure to do so will cause the epoxy system to harden on the tools and equipment making it very difficult to remove. Consult SDS for safety and health precautions.
- Maintenance
Terrazzo flooring made with TERRAZZCO® Terraglow™ is simply cleaned with neutral soaps or detergents. Regular mechanical scrubbing is recommended for all surfaces having a non-skid texture. Long periods of heavy foot traffic may necessitate reapplication of a finish coat. We also advise the owner to consult the National Terrazzo & Mosaic Association guidelines for maintaining terrazzo surfaces.
- Design Applications
Architects and designers can custom match this glow-in-the-dark epoxy resin system with a flooring design or wayfinding patterns. Terraglow can also be used in precast terrazzo applications, including multi-color abrasive strips as a safety precaution for terrazzo staircases.
- Glow-In-The-Dark Abrasive Strips
In addition to epoxy resin and aggregates, Terraglow can also be manufactured as abrasive strips. Add abrasive strips to any terrazzo stair tread for a unique appearance that offers a safe guide to anyone traveling under low-light conditions.
The abrasive strips are routed out channels that are then filled with Terraglow epoxy resin. The resin is bonded directly to the terrazzo stair tread. The epoxy can be poured into the channels by itself for a smooth finish or you can incorporate aluminum oxide for abrasive resistance. Terraglow abrasive strips come in multiple colors as well.
Properties
- Physical Properties
Value | Units | Test Method / Conditions | |
Hardness | 83.5 | — | ASTM D-2240 |
Tensile Strength | 9890.0 | psi | ASTM D-638 |
Compressive Strength | 13200.0 | psi | ASTM D-695 |
Flexural Strength | 4500.0 | psi | ASTM D-790 |
Flammability | max. 0.25 | inch | ASTM D-635 |
Bond Strength | 400.0 | psi | ACI COM 403 |
Thermal Coefficient of Linear Expansion | 17.4 | 10^-6 / °F | ASTM D-696 |
Regulatory & Compliance
- Greenguard Certification
TERRAZZCO™ Groutless™ EZPour Epoxy 158 is GREENGUARD and GREENGUARD Gold certified tested and proven by thirdparty organizations to have low-VOC emissions. GREENGUARD Certification identifies products that meet indoor air quality guidelines and standards, and is a valuable tool for architects, product specifiers, and designers that want to locate, specify and purchase low-emitting products for indoor environments.
Technical Details & Test Data
- Considerations
- Substrate temperature must be between 55o and 90o F before, during and 72 hours after installation. The surface temperature of the concrete must be 5o above the dew point to ensure proper curing of the terrazzo floor.
- Substrate must be free of dirt, waxes, curing agents, and other foreign materials. The concrete surface must be prepared by shot blasting or by grinding.
- All control joints and expansion joints in the substrate must be revealed with the appropriate divider strips in the terrazzo topping.
- An active vapor barrier must be present under concrete slab.
- Materials should be allowed to acclimate to controlled application environmental conditions prior to being mixed.
- Material is not designed to be used as a moisture vapor barrier.
- Working Data
Working (Pot) Life 40-50 minutes @ 75°F
Full Set Time 18-24 hours @ 75°F
Full Cure and Maximum Performance 5-10 days - Cured Resin Properties
Property Test Method Result Chemical Resistance
ASTM D-1308
No Deleterious Effects: Distilled Water Mineral Water 10% Sodium Hydroxide Isopropanol 10% Hydrochloric Acid 0.025 Detergent Solution
5% Acetic Acid Ethanol 1% Soap Solution 30% Sulfuric Acid
Safety & Health
- Safety
Federal, state, and local guidelines must be followed during the handling and installation of these materials. Any excess material should be disposed of according to applicable federal, state, and local codes.
Packaging & Availability
- Packaging
TERRAZZCO® Terraglow™ resin part A is packaged in 5 gallon pails or 55 gallon drums. TERRAZZCO® Terraglow™ hardener part B is packaged in one gallon cans, or 5 gallon pails.
- Color & Availability
TERRAZZCO® Terraglow™ is available in four epoxy resin colors: Blue, Green, Violet & Aqua.
- Warranty
TERRAZZCO® products are warranted for a period of one (1) year. Warranty provides that the product will be free of manufacturing defects and will be in conformity with published specifications when handled, stored, mixed and applied in accordance with recommendations of TERRAZZCO® literature. If any product fails to meet this warranty, the liability of manufacture will be limited to replacement of any non-conforming material if notice of such non-conformity is given to manufacturer within (1) one year of delivery of materials. Manufacturer may in its discretion refund the price received by them in lieu of replacing the material. No customer or distributor of TERRAZZCO® products is authorized to change or modify the published specifications of this warranty in any way. No one is authorized to make oral warranties on behalf of manufacturer. In order to obtain replacement or refund the customer must provide written notice containing full details of the non-conformity. Manufacturer reserves the right to inspect the non-conforming material prior to replacement.
Storage & Handling
- Storage Conditions
It is suggested that materials are stored in a temperature and humidity controlled environment. If this is not possible materials should be allowed to acclimate to controlled environmental conditions of application. Keep resins and hardeners separated from each other until ready for use. Materials should be kept away from sources of ignitions. Materials should be stored in their original unopened container. Epoxy resin does not have a shelf life and hardener has a 1 year shelf life when stored in the above described manner.