Product Type: 2K (2 component) Coating, Epoxy Coating

Features: Abrasion Resistant, Acid Resistant, Alkali Resistant, Chemical Resistant, Good Adhesion, Good Flexibility, High Hardness, High Impact Resistance, Long Term Protection, Low VOC, Water Resistant

Application Area: Pipes, Tanks

Compatible Substrates & Surfaces: Concrete, Metal, Steel

Application Method: Brush, Spray

Chemical Family: Polyamides

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Gloss
Semi-Gloss

Features & Benefits

Features
  • 0.4 Ibs/gal (50 g/l) VOC.
  • Excellent resistance to water, seawater, wastewater, alkaline water and acidic water.
  • Good impact resistance.
  • Excellent flexibility, hardness, and adhesion.
  • Excellent abrasion resistance.
  • No primer required.
  • High build 16 to 25 mils (406 to 635 microns) in one coat.
  • Can be used with cathodic protection systems.
  • Exceeds Corp of Engineers C-200, C200a.
  • Exceeds AWWA C-210 for exterior.
  • Can be brush or spray applied.

Applications & Uses

Application Area
Application Method
Compatible Substrates & Surfaces
Uses

For long-term corrosion protection of steel and concrete substrates against water, wastewater, seawater, alkaline water and acidic water corrosion. Designed to coat steel piles, sheet piles, lock gates, reservoirs, non-potable water pipelines, treatment / storage tanks, bridges and many other aggressive industrial applications.

Application

Steel: All contaminants shall be removed from the steel surface to be coated. Remove oil, dust, and grease and other contaminants that could interfere with adhesion of the coating. Surfaces shall be free from projections, sharp edges, high points and fi llets must be ground smooth including all corners. For immersion service, prepare surfaces by grit blasting to a clean near-white finish, SSPC-SP 10 or NACE No. 2. For non-immersion service, prepare surfaces using SSPC-SPC6 or NACE No.3. Appropriate angular grit shall be used to achieve a 2.0 to 4.0 mil (50 to 100 microns) anchor profile.

Concrete: Concrete must be cured 28 days at 77°F (25°C) and 50% relative humidity. All surfaces shall me prepared in accordance with ASTM D4258 and ASTM D4259. All voids in concrete shall be filled and repaired.

Spray: A single leg airless unit shall be used. The unit shall be a minimum of 68:1 airless pump. A wet-on-wet spray technique should be used to achieve 11 to 22 mils (280 to 559 microns). The coating thickness should be measured using a wet-fi lm thickness gage.

Mixing: Power mix both A & B separately then combine and power mix thoroughly for two minutes. Do not mix partial kits.

Cleaning

Clean equipment with Xylene, Toluene or equivalent solvent cleaner. If work stoppage happens, then all material must be cleared out as to not allow product to set within equipment.

Properties

Technical Data
ValueUnitsTest Method / Conditions
Abrasion Resistance (1000 cycles, CS17 wheel, 1000 gram load)111.0mg lossASTM D 4060-01
Adhesion23.4MPaASTM D4541
Dry Film Thickness203 - 407microns per coat
Dry to Touch (10°C)6.0hours
Dry to Touch (25°C)3.0hours
Dry to Touch (32°C)1.5hours
Final Cure Immersion Service (10°C)14.0days
Final Cure Immersion Service (25°C)7.0days
Final Cure Immersion Service (32°C)5.0days
Flash Point5.0°C
Hot Salt Fog (35°C)2000.0hoursASTM B117
Minimum Dewpoint / Substrate Differential3°C
Overcoating Time (25°C)min. 5hours
Pot Life (25°C)2.0hours
Pot Life (32°C)1.0hour
Ratio by Volume (A to B)4:1
Solids by volume80.0%
Specific Gravity1.4
Spray Equipment Required (Airless)68:1
Substrate Temperaturemin. 5°C
Temperature (Atmospheric)94.0°C
Temperature (Immersion)54.0°C
Theoretical Coverage (406 microns)1.96m2/L
Top CoatNot Recommended
VOC50.0g/L
Wet Film Thickness280 - 559microns per coat

Safety & Health

Health & Safety

Wear protective clothing and ensure adequate ventilation. Avoid contact with skin and eyes. See safety data sheet for further information.

Packaging & Availability

Packaging

1 gallon (3.8 liter) and 5 gallon (19 liter) kits.

Other sizes available upon request.

Storage & Handling

Storage

Minimum 18 months when stored in original unopened containers at 41°F (5°C) to 110°F (43°C).