company tower banner
Duromar Company Logo

Duromar® DF-1301

1 of 8 products in this brand
Duromar® DF-1301 is a clear, 100% solids concrete sealer with excellent flexibility and moderate chemical resistance. It is used primarily to seal the concrete prior to the application of additional topcoats, to prevent outgassing, and to restore the mechanical properties of old concrete. It can be cured at temperatures as low as 50ºF. Duromar® DF-1301 is a multifunctional epoxy with a uniquely modified cycloaliphatic amine hardener.

Product Type: Epoxy Coating, Sealer, Solventless & High Solids Coating

Compatible Substrates & Surfaces: Concrete

Features: High Solids Content, Low Temperature Curing

Application Method: Brush, Roller, Trowel

Chemical Family: Epoxy & Epoxy Derivatives

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Ready-to-Use Product Features

Applications & Uses

Application Method
Compatible Substrates & Surfaces
General Application Guidelines

Storage: Store all product in a clean, warm area where the temperature remains between 50-110ºF (10-43ºC). Cold products are very viscous and will be difficult to mix and apply. Products shipped during cold months can remain cold for many days even when stored as recommended. Paste or trowel applied products will remain cold longer than liquid or spray applied products. Heating of the individual components may be required to bring the products to the recommended temperatures.

Surface Preparation: SSPC-SP 13

All surfaces to be lined are to be clean, dry, and oil free. Refer to the DUROMAR Information and Application Guide for specific instructions for various surfaces such as concrete, metal fiberglass, etc.

  • Minimum surface temperature during application - refer to Product Data Sheet.
  • For Brush, Roller, or Spray Applied Products, the surface profile must be 3 mils minimum.
  • For Trowel Applied Products, the surface profile must be 4 mils minimum.

Application Equipment:

  • Brushes - short bristle, nylon, and non-shedding. Replace when products become hot or stiff.
  • Rollers - short nap (3/8” max.) nonshedding, with a polyethylene core. Replace when products become hot or stiff.
  • Airless Spray Equipment – Single, Plural recommendations are listed in the DUROMAR Information and Application Guide.

Mixing:

  • Do not add solvent to any DUROMAR product. These 100% solids materials are formulated to be applied as shipped after proper mixing.
  • The temperature of the Hardener (A) and Base (B) portions should be between 70-80ºF (20-25ºC). Mix them separately to insure a uniform consistency.
  • Add the entire contents of the Hardener (A) to the Base (B) bucket. Use a brush or squeegee to assist in the transfer. These portions are accurately measured and best product performance will be obtained if all the Hardener and Base is combined. Pouring from one container to the other (boxing) during mixing is very helpful in insuring complete mixing.
  • Mix the products until no streaking is observed and then for about one (1) minute longer.

Application:

  • For hand application, immediately break down the full unit into smaller portions such as roller pans, small buckets, or trowel boards. This will keep the product cooler and improve the useable life.
  • For spray application using a single or plural component airless system, see Section 4 in the DUROMAR Information and Application Guide. Make sure all components are working according to the airless equipment manufacturers’ instructions and the product components are at the recommended temperature before spraying.

Overcoating: When applying multiple coats of any epoxy products, always check for Amine Blush before applying the next coat. Amine Blush may occur when the epoxy surface is cool or in humid environments. It has the appearance and feel of a light oil film on the surface. When dry it has a white chalky appearance. If detected, wash the surface with a 2% hydrochloric acid solution followed by a water wash until the surface pH is between 6-8. Allow to dry before applying the next coat.

Clean Up: Most solvents and commonly used thinners such as MEK, acetone, xylene, I,I,I trichloroethane, and safety solvents such as Ensolv, etc., can be used for cleaning tools and equipment. However, as many of these materials are flammable or present other safety hazards, the user should read the MSDS for these materials before using. In no event should these materials be used to clean material from the skin, eyes or clothing.

Application Information
Pot Life at 70ºF 50 min.
Equipment Brush, Roller, Trowel, Airless Spray
Number of Coats 1
Theoretical Coverage 320 ft²/gal at 5 mils
Film Thickness/Coat As Required

Recoat Time at 70ºF

min. 6 hrs
max. 96 hrs
Min. Application Temp. 50ºF
Mixing Ratio by Weight 4.4 : 1 (B/A)
Mixing Ratio by Volume 3.8 : 1 (B/A)
Dry to Touch 6 hrs

Properties

Appearance
Clear Gloss
Typical Physical Properties
ValueUnitsTest Method / Conditions
AdhesionExcellent--
Dry Operating Temperaturemax. 250ºF-
FlexibilityExcellent--
Full Cure120.0hours-
Functional Cure24.0hours-
Surface PreparationSSPC-SP 1,3,7--
Typical Properties
ValueUnitsTest Method / Conditions
Components2.0--
Density1.09--
Solids by Weight100.0%-
Chemical Resistance
ValueUnitsTest Method / Conditions
Alkalis (70ºF)Good--
Hydrocarbons (70ºF)Good--
Inorganic Acids (70ºF)Good--
Organic Acids (70ºF)Fair--
pH Range (70ºF)3.0 - 13.0--
Solvents (70ºF)Fair--

Safety & Health

Health & Safety

Eye and skin irritant. May cause dermatitis and sensitization. Always read and understand the product MSDS. Avoid contact with eyes, skin or clothing. Avoid breathing vapor, mist or spray. Use with good ventilation.

First Aid in case of contact:

  • Eyes: Immediately flush with water for at least 15 minutes.
  • Skin: Immediately remove from skin with dry cloth followed by thorough washing with soap and water.
  • Inhalation: Remove to fresh air. If breathing is difficult, give oxygen.
  • Ingestion: Give large quantity of milk or water, induce vomiting. Contact a physician immediately.

Storage & Handling

Storage / Shelf Life

This product has a minimum shelf life of one year when stored in a dry area at 50-110ºF in the original sealed container.