Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Features
- Zero VOC, solvent-free, no odor.
- 100x more breathable than a standard epoxy flooring system.
- Excellent adhesion to properly prepared concrete.
Applications & Uses
- Applications
- Compatible Substrates & Surfaces
- General Application Guidelines
Storage: Store all product in a clean, warm area where the temperature remains between 60-90ºF (15-30ºC). Cold products are very viscous and will be difficult to mix and apply. Products shipped during cold months can remain cold for many days even when stored as recommended. Paste or trowel applied products will remain cold longer than liquid or spray applied products. Heating of the individual components may be required to bring the products to the recommended temperatures.
Surface Preparation: (SSPC-SP 1)
All surfaces to be lined are to be clean, dry, and oil free. Refer to the Application Manual for specific instructions for various surfaces such as concrete, metal fiberglass, etc.
- Minimum surface temperature during application - refer to Product Data Sheet.
- For Brush, Roller, or Spray Applied Products, the surface profile must be 3 mils minimum.
Application Equipment:
- Brushes - short bristle, nylon, and non-shedding. Replace when products become hot or stiff.
- Rollers - short nap (3/8” max.) nonshedding, with a polyethylene core. Replace when products become hot or stiff.
- Airless Spray Equipment and Application recommendations are listed in the DUROMAR Application Manual.
Mixing:
- Do not add solvent to any DUROMAR product. These 100% solids materials are formulated to be applied as shipped after proper mixing.
- The temperature of the Hardener (A) and Base (B) portions should be between 70-80ºF (20-25ºC). Mix them separately to insure a uniform consistency.
- Add the entire contents of part (B) Base, and 40 ounces (1.2 liters) of clean water for a 1 gallon unit, to the Hardener (A) bucket. Mix thoroughly until all materials are completely incorporated and there is no streaking. Use a brush or squeegee to assist in the transfer. These portions are accurately measured and best product performance will be obtained if all the Hardener and Base is combined. Pouring from one container to the other (boxing) during mixing is very helpful in insuring complete mixing.
Application:
- For hand application, immediately break down the full unit into smaller portions such as roller pans, small buckets, or trowel boards. This will keep the product cooler and improve the useable life. For spray application using a single component airless system, see Section 4.4.1 of DUROMAR Application Manual.
- For spray applications using plural component equipment make sure all components are working according to the manufacturers’ instructions and the product components are at the recommended temperature before spraying.
Amine Blush:
When applying multiple coats of any epoxy products, always check for Amine Blush before applying the next coat. Amine Blush may occur when the epoxy surface is cool or in humid environments. It has the appearance and feel of a light oil film on the surface. When dry it has a white chalky appearance. If detected, wash the surface with a 2% hydrochloric acid solution followed by a water wash until the surface pH is between 6-8. Allow to dry before applying the next coat.
- Application Information
Pot Life at 70ºF 45 min Equipment Brush, Roller Number of Coats 1 Theoretical Coverage 160 ft²/gal at 10 mils Film Thickness/Coat
min. 3 mils max. 10 mils Max. DFT 10 mils Recoat Time at 70ºF
min. 4 hrs max. 96 hrs Min. Application Temp. 50ºF Mixing Ratio by Weight 3:4 (B/A) Dry to Touch 4 hrs
Properties
- Appearance
- Clear Gloss
- Typical Physical Properties
- Typical Properties
- Chemical Resistance
Value | Units | Test Method / Conditions | |
Adhesion | Excellent | - | - |
Dry Operating Temperature | max. 250 | ºF | - |
Flexibility | Good | - | - |
Full Cure | 120.0 | hours | - |
Functional Cure | 24.0 | hours | - |
Surface Preparation | SSPC-1 | - | - |
Value | Units | Test Method / Conditions | |
Components | 3.0 | - | - |
Density | 1.07 | - | - |
VOC Content | 0.0 | % | - |
Value | Units | Test Method / Conditions | |
Alkalis (70ºF) | Excellent | - | - |
Hydrocarbons (70ºF) | Good | - | - |
Inorganic Acids (70ºF) | Good | - | - |
Organic Acids (70ºF) | Good | - | - |
pH Range (70ºF) | 2.5 - 14.0 | - | - |
Solvents (70ºF) | Good | - | - |
Safety & Health
- Health & Safety
Eye and skin irritant. May cause dermatitis and sensitization. Always read and understand the product MSDS. Avoid contact with eyes, skin or clothing. Avoid breathing vapor, mist or spray. Use with good ventilation.
First Aid in case of contact:
- Eyes: Immediately flush with water for at least 15 minutes.
- Skin: Immediately remove from skin with dry cloth followed by thorough washing with soap and water.
- Inhalation: Remove to fresh air. If breathing is difficult, give oxygen.
- Ingestion: Give large quantity of milk or water, induce vomiting. Contact a physician immediately.
Storage & Handling
- Storage / Shelf Life
This product has a minimum shelf life of one year when stored in a dry area at 50º-100ºF in the original sealed container.