Knowde Enhanced TDS
Identification & Functionality
- Carrier
- Chemical Family
- CASE Ingredients Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
Applications & Uses
- Applications
- Application Method
- Compatible Substrates & Surfaces
- Coating Type
- Product Applications
- L-3790 may be applied by spray or gravure methods.
- Films must be dried completely before UV energy cure.
- UV irradiation is required to attain optimal film properties, but un-cured coating films are durable enough for handling prior to curing.
Properties
- Physical Form
- Physical Properties
Value | Units | Test Method / Conditions | |
Solids | 34 - 36 | % | — |
Viscosity | 50 - 500 | cps | — |
pH | 7.5 - 10.0 | — | — |
Density | 8.8 | lbs/gal | — |
Softening Point (uncured) | 290 | °F | — |
Softening Point (cured) | 500 | °F | — |
VOC Content (as supplied) | 75 | gm/l | — |
VOC Content (less water) | 192 | gm/l | — |
Sward Hardness (after UV-curing) | 64 | — | — |
Technical Details & Test Data
- Curing
- L-3790 must be air-dried, or oven dried (temperature: 150 - 170° F; dwell time: 10 minutes) to remove water from the film prior to UV exposure.
- A photo-initiator must be incorporated into the coating formulation for effective curing.
- See starting point formulations for suggestions. Exposure guidelines: MPMA lamp - 300 watts/in² , 2.0 - 3.0 second dwell time.