Knowde Enhanced TDS
Identification & Functionality
- Product Type
- Technologies
- Product Families
Applications & Uses
- Markets
- Applications
- Usage
For priming and sealing dusty, absorbent surfaces to improve bonding of asphalt coatings and finishes. Used for priming thermal insulation, concrete, masonry, gypsum, asbestos, asphalt roofing felts and similar surfaces.
- Application
Prep: Surfaces must be dry and free from dust, dirt, grease and other foreign matter.
Apply by brush, roller or spray. Protect new work from open flame or adjacent welding activity. Avoid use where solvent odors may taint food or other susceptible products. Do not apply over coal-tar coatings. Do not apply to wet surfaces.
- Cleanup
Use mineral spirits.
Properties
- Color
- Physical Properties
Value | Units | Test Method / Conditions | |
Application Temperature (Ambient) | May be applied at low temperature | - | - |
Coverage (Depending on porosity of surface) | 2 - 10 | m²/l | - |
Drying Time (Firm Dry, 50% R.H. 20°C ) | 8 - 24 | Hours | - |
Drying Time (Touch Dry, 50% R.H. 20°C ) | 1.0 | Hours | - |
Flammability (Dry) | Burns | - | - |
Flammability (Wet) | Combustible | - | - |
Service Temp (coated face) | -30 to 85 | °C | - |
Solids (by Volume) | 37.0 | % | - |
Solids (by Weight) | 0.87 | kg/l | - |
Regulatory & Compliance
- Quality Standards
- Approvals and Certifications
Complies with CGSB 37-GP-9M and ASTM D-41, Type II
Safety & Health
- Caution
Contains flammable solvents. Take suitable fire precautions. Do not allow smoking or welding in working area. Keep away from heat and open flame. Use in well-ventilated areas. Keep containers covered when not in use. Harmful if swallowed.
Packaging & Availability
- Product Size
5 gallon (18.93L) – 39.1 lb