Knowde Enhanced TDS
Applications & Uses
- Applications
- Brush, roller, conventional and airless spray.
- DC315 is for interior use as a thermal or ignition barrier coating to protect SPF.
- Contact IFTI for instruction for using DC315 in other applications such as, but not limited to, cold storage, parking garages, high humidity, or any unconditioned spaces.
- Recommended Sprayer
Pump (Graco) UltraMax 795 or equivalent PSI 3000 GPM 1.1 Tip 517 - 523 or equivalent. Filter Removal from the machine and gun is required Hose 3/8" diameter airless spray line for the first 100’ from pump and 1/4" x 3’ whip Pump (Graco) TexSpray Mark 5 or equivalent PSI 3300 GPM 1.35 Tip 517 - 523 or equivalent. Filter Removal from the machine and gun is required Hose 3/8" diameter airless spray line for the first 100’ from pump and 1/4" x 3’ whip Pump (Graco) GMAX 7900 or equivalent PSI 3300 GPM 2.2 Tip 517 - 529 or equivalent. Filter Removal from the machine and gun is required Hose 1/2" diameter airless spray line for the first 100’ 300’ from pump and 1/4" x 3’ whip Pump (Graco) GH 833 or equivalent PSI 4000 GPM 4 Tip 517 - 529 or equivalent. Filter Removal from the machine and gun is required Hose 1/2" diameter airless spray line for the first 100’-300’ from pump and 1/4" x 3’ whip
Properties
- Specifications
Value | Units | Test Method / Conditions | |
Finish | Flat | — | — |
VOC | 47.0 | g/L | — |
Volume Solids | 67.0 | % | — |
Drying Time (77°F, 50%RH, To Touch) | 1 - 2 | hours | — |
Drying Time (77°F, 50%RH, To Recoat) | 2 - 4 | hours | — |
Type of Cure | Coalescence | — | — |
Reducer or Cleaner | Water | — | — |
Regulatory & Compliance
- Regulatory & Compliance
- Building Code Fire Performance Requirements for SPF: The International Building Code (IBC) mandates that SPF be separated from the interior of the building by a 15-minute thermal barrier, or other approved covering.
- DC315 Carries IAMPO ER-0499 and ICC-ESR 3702 Evaluation Reports confirming that DC315 meets IBC and IRC Code Requirements.
- DC315 has also been tested as an ignition barrier under AC 377 Appendix X.
- More certified full-scale alternative Thermal and Ignition Barrier tests than any other product in the world
- DC315 manufacturing facilities are 3rd. the party was inspected for Quality Control.
- Listed under Warnock Hersey Intertek W/N 20947
- Tested useful life, fire-resistant property is not compromised after 50 years
- Topcoat for color, weather, and moisture protection tested via NFPA 286 full-scale testing
- ANSI 51 testing for incidental food contact
- Passed CAL 1350 – qualifies DC315 as a low-emitting material in the Collaborative for High-Performance Schools rating system (CHPS Designed & CHPS Verified)
- Passed strict EPA – VOC and AQMD air emission requirements
- Single Coat Coverage up to 24 Mils WFT on ceilings and walls - reducing labor costs equaling higher profits
- Meets Life Safety Code 101
- Meets LEED’s point requirements
- No formaldehyde
Technical Details & Test Data
- Performance
50+ years HOAC tested.
- Testing
USA:
- ASTM E84 - Flame Spread 0 Smoke 10
- NFPA 286, UL1715
- ASTM E2768- 30 minute Ignition Resistant material
Canada:
- CAN/ULC S102 FSR 23 SDC 145 - (tested as a system over SPF)
- CAN/ULC S 101
- CAN/ULC 9705 10 and 20 minute assembly testing
European Union:
- BS 476 Part 6 & 7
- BS EN ISO 11925-2
- EN 13823
- EN 13501 Classification B S2 D0
Australia/New Zealand:
- AUS ISO 9705
- AS/NZS 1530.3
- AS 5637.1 Group Classification 2, NZBC Group 2-S
- ISO 5660 Parts 1 and 2
Packaging & Availability
- Packaging
5 & 55 gallon containers
- Shipping Weight
- 5 gallon pail - 58 lbs.
- 55 gallon drum - 640 lbs.
Storage & Handling
- Shelf Life
- 1 year (Unopened)