Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Heat Transfer Fluid Type
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Performance Advantages
- Ideal for open-bath systems
- Impervious to oxidation - Ideal for systems prone to premature fluid degradation
Applications & Uses
- Markets
- Applications
- Open-bath systems
- Closed loop systems with a maximum bulk temperature of 601°F (316°C)
- Open loop systems with a maximum bulk temperature of 400°F (204°C)
Properties
- Typical Properties
Value | Units | Test Method / Conditions | |
Minimum Temperature | -63 (-53) | °F (°C) | - |
Maximum Film Temperature | 691 (366) | °F (°C) | - |
Maximum Bulk Temperature | 601 (316) | Closed System | - |
Maximum Bulk Temperature | 400 (204) | Open Systems | - |
Pour Point | -87 (-66) | °F (°C) | - |
Flash Point | 615 (324) | °F (°C) | - |
Fire Point | 637 (336) | °F (°C) | - |
Autoignition Point | 819 (437) | °F (°C) | - |
Thermal Expansion Coefficient | 0.105 | %/°C | - |
Thermal Conductivity ( 38°C) | 0.133 | W/m-K | - |
Thermal Conductivity ( 260°C) | 0.101 | W/m-K | - |
Heat Capacity ( 38°C) | 1.714 | kJ/kg-K | - |
Heat Capacity ( 260°C) | 2.137 | kJ/kg-K | - |
Distillation Range (10%) | 494.0 | °C | ASTM D2887 |
Distillation Range (90%) | 679.0 | - | - |