Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Technologies
- Product Families
Features & Benefits
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Fields Of Use
Mechanical, aeronautical, chemical, electrical, construction sectors in semi-finished products such as pipes, fittings, plates, solid bars and profiles. They are obtained: tanks, plant components, fans, parts of submersible pumps, rings, flanges, pulleys, gears.
Properties
- Mechanical Properties
- Physical Properties
- Typical Properties
- Thermal Properties
- Electrical Properties
- Flammability
Value | Units | Test Method / Conditions | |
Yield Strength | 32 | MPa | ISO 527 |
Elongation (Yield) | 8 | % | ISO 527 |
Elongation (Break) | 70 | % | ISO 527 |
Tensile Modulus | 1600 | MPa | ISO 527 |
IMPact Strength (Un-Notched) | NB | KJ /m2 | ISO 179 |
IMPact Strength (Notch) | 7 | KJ /m2 | ISO 179 |
Hardness (Shore D) | 72 | Shore D | DIN 53505 |
Compressive Stress (1% Strain-23°C) | 14 | MPa | ISO 604 |
Value | Units | Test Method / Conditions | |
Specific Gravity | 0.95 | g/cm3 | ISO 1183 |
Water (Absorption At Saturation) | 0.1 | % | ISO 62 |
Moisture (Absorption At 23°C - 50% RH) | 0.05 | % | ISO 62 |
Value | Units | Test Method / Conditions | |
Bondability | Bonding and painting are possible after special surface treatment. | — | — |
Uv Resistance | No. | — | — |
Value | Units | Test Method / Conditions | |
Maximum Operating Temperature | 100 | °C | — |
Minimum Operating Temperature | 0 | °C | — |
Vicat Softening Temperature (VST/B/50) | 87 | °C | ISO 306 |
Thermal Conductivity (23°C) | 0.22 | W/(K*m) | DIN 52612 |
Coef. Of Linear Thermal Expansion (23°C) | 160 | μm | ASTM D696 |
Value | Units | Test Method / Conditions | |
Volume Resistance | min.10^16 | Ω | IEC 60093 |
Surface Resistance | 10^14 | Ω | IEC 60094 |
Dielectric Constant (1 MHZ) | 2.2 | abs | IEC 60250 |
Dielectric Loss Factor (1 MHZ) | 0.0012 | tan | IEC 60250 |
Dielectric Witch (2mm) | 22 | KV/mm | IEC 60243 |
Value | Units | Test Method / Conditions | |
Flammability | V2 | — | UL 94 |
Regulatory & Compliance
- Food Contact Safety (FDA Compliance)
NO (Test Method DM 21.3.73)