Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Technologies
- Product Families
Features & Benefits
Applications & Uses
- Applications
- Plastics & Elastomers End Uses
- Fields Of Use
Mechanical, chemical, electrical sectors, mainly used in the construction of tanks for industrial plants, suction hoods, scrubbers, gears, penstocks for water and the chemical industry, drainage and drainage pipes, and general plant engineering for the purification of waste water.
Properties
- Physical Properties
- Mechanical Properties
- Typical Properties
- Thermal Properties
- Electrical Properties
- Flammability
- Tribological Properties
Value | Units | Test Method / Conditions | |
Specific Gravity | 1.4 | g/cm3 | ISO 1183 |
Water (Absorption At Saturation) | 0.2 | % | ISO 62 |
Moisture (Absorption At 23°C - 50% RH) | 0.2 | % | ISO 62 |
Value | Units | Test Method / Conditions | |
Yield Strength | 49 | MPa | ISO 527 |
Elongation (Yield) | 10 | % | ISO 527 |
Tensile Strength (Break) | 30 | MPa | ISO 527 |
Elongation (Break) | 30 | % | ISO 527 |
Tensile Modulus | 2600 | MPa | ISO 527 |
IMPact Strength (Un-Notched) | NB | KJ /m2 | ISO 179 |
IMPact Strength (Notch) | 10 | KJ /m2 | ISO 179 |
Hardness (Shore D) | 78-80 | Shore D | DIN 53505 |
Flexural Strength (3.5%) | 80 | MPa | ISO 178 |
Value | Units | Test Method / Conditions | |
Bondability | Yes | — | — |
UV Resistance | Resistance to UV exposure is reached with the pigmentation or specific additive. | — | — |
Value | Units | Test Method / Conditions | |
Maximum Operating Temperature | 60 | °C | — |
Minimum Operating Temperature | -40 | °C | — |
Vicat Softening Temperature (VST/B/50) | 73 | °C | ISO 306 |
Heat Deflection Temperature (0.45 MPa) | 69 | °C | ISO 75 |
Thermal Conductivity (23°C) | 0.17 | W/(K*m) | DIN 52612 |
Coef. Of Linear Thermal Expansion (23 To 100°C) | 80 | μm | ASTM D696 |
Value | Units | Test Method / Conditions | |
Volume Resistance | min.10^15 | Ω | IEC 60093 |
Surface Resistance | min.10^13 | Ω | IEC 60094 |
Dielectric Constant (1 MHZ) | 3 | abs | IEC 60250 |
Dielectric Loss Factor (1 MHZ) | 0.01 | tan | IEC 60250 |
Dielectric Witch (2mm) | 20-40 | KV/mm | IEC 60243 |
Value | Units | Test Method / Conditions | |
Flammability | V1 | — | UL 94 |
Value | Units | Test Method / Conditions | |
Dynamic Coef. Of Friction On Polished Steel | 0.52 | abs | MPC test |
Pv Limit Without Lubrication | 0.6 | MPa | MPC test V = 0.5 m / s MPC |
Regulatory & Compliance
- Food Contact Safety (FDA Compliance)
NO (Test Method DM 21.3.73)