PolyBrite® 90 is a premium grade high solids, moisture cure, liquid applied silicone coating available in white or as tinted, which cures to form a seamless membrane when applied over the entire roof area. It also keeps the surface cool, providing protection from ultraviolet sun and other weather exposures.

Product Type: Solventless & High Solids Coating

Features: Fungus Resistant, Good UV Protection, Good Weather Stability, High Elongation, High Solids Content, High Temperature Resistance, High Tensile Strength

Application Area: Roofing Substrates

Compatible Substrates & Surfaces: Concrete, Metal, Polyurethane

Application Method: Brush, Roller, Spray

Chemical Family: Silicones

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family

Features & Benefits

Features & Benefits
  • Excellent resistance to weathering including: UV radiation, extreme temperatures, as well as rain, ice and snow.
  • Extends the useful life of the roof.
  • PolyBrite 90 can reduce energy costs by decreasing roof surface temperature.
  • Fungal and algal resistant – even in high temperatures.
  • Non-flammable and presents minimal hazard to the applicator or the environment.
Benefits
  • Polyglass offers all the product components needed for these systems – one stop shop
  • A variety of systems which can be used on new construction or tear off and replace roofs
  • Offers excellent resistance to extended exposure to solar ultraviolet energy
  • Can decrease the roof surface temperature, thereby reducing energy costs
  • Superior tensile strength for a strong roof
  • Easy to install, no kettle, no torch and no special tools or equipment needed other than a heavy roller
  • Much safer than traditional hot asphalt BUR or torch down systems
  • Should reduce the cost of insurance for the roofing contractor
  • Low VOC and odor - presents minimal hazard to the applicator or the environment
  • Resistant to dirt pick-up – easy to maintain
  • Fungal and algal resistant

Applications & Uses

Application Area
Application Method
Compatible Substrates & Surfaces
Cure Method
Uses
  • Protect and waterproof a variety of roof surfaces.
  • Suitable for use on sprayed polyurethane foam, most metal roof systems, concrete, Thermoplastic and Thermoset single-ply membranes (primer may be required). Suitable for use over various conventional BUR and polymer modified roof membranes with smooth and mineral surfacing when primed with PolyBrite 97X Epoxy Primer or PolyBrite 98 one-part acrylic primer/bleed blocker. Contact Polyglass Technical Services for clarification of unusual surfaces or project conditions.
Application Instruction

Surface Preparation

  • All surfaces to receive coating must be clean, dry and free from any foreign matter such as dirt, oils, grease or other debris that could inhibit the adhesion capabilities of the newly installed products.
  • Metal surfaces that display rusting or other oxidation, to be prepared with a grinder or wire brush as needed to remove surface contaminants.
  • Existing roof systems to be visually inspected for conditions that may adversely affect adhesion of performance of newly installed products. Repair any visible deficiencies such as splitting, blistering, and buckling with PolyBrite 72 or PolyBrite 73 Elastomeric Mastic and PolyBrite Polyester Fabric.
  • Visually inspect all metal and non-metal flashings, edges, drains, valleys and through-roof penetrations and repair as needed by project conditions.
  • Do not apply to wet or visibly damp surfaces, or surfaces previously covered with coal tar based products or Kynar® finishes.
  • Concrete surfaces cured with wax/resin based compounds can inhibit adhesion.

Application

  • Stir well prior to application.
  • PolyBrite 90 is recommended to be applied with high pressure sprayer for best appearance and coverage. It may also be applied by roller or brush applications.
  • Apply PolyBrite 90 at 20 wet mils (1.25 gallon per 100 square feet) per coat. Typical application conditions require PolyBrite 90 be applied in two coats at 20 wet mils per coat. Consult Polyglass Technical Services for application rates for specific roof membranes and for job specific application specifications.
  • Subsequent coats should be applied within 24 hours of prior applications to insure full and uniform adhesion. Coating must be evenly applied and pinhole-free. Before applying a subsequent coat of this product, the previous coat must be completely dry and cured. Apply second coat perpendicular to the first.
  • Apply only when ambient temperatures are 50ºF and rising. Cold weather could result in uneven application and improper curing of product. Do not apply if there is a threat of inclement weather within 4 hours of application. Drying time is dependent on temperature, humidity and film thickness.
  • Do not thin product.
  • Prior to using this product on new cap sheets (smooth or granulated), it is recommended to wait 30 days for weathering.

Application Equipment

This product may be sprayed, brushed, or rolled. Due to the high viscosity of the material, a high-pressure airless paint pump capable of producing 5000 PSI should be used. The pump should have a minimum of 2.5 gallons per minute output and be fed by a 5:1 transfer pump to prevent cavitation. Always use components rated for pump pressure. Hoses should be BUNA-N jacketed for prevention of moisture contamination. Hoses should have a minimum I.D. of 3⁄4" and an adequate working pressure. The spray gun should be high pressure (5000 PSI) with reverse-a-clean spray tip, 0.029–0.035 and a 50° fan tip. Any filters on spray rig or gun should be removed. Filters are required when applying fine finishes but not for roof coatings.

Do not use fan tip. Any filters on spray rig or gun should be removed. Filters are required when applying fine finishes but not for roof coatings.


Cleaning

Cleanup of spray equipment containing uncured material may be accomplished by flushing with VM&P Naphtha or mineral spirits. PolyBrite 90 cures by reacting with moisture and should not be left in spray guns, pump equipment and hoses for prolonged periods unless equipment contains moisture lock hoses, fittings and seals. Equipment without these components will transmit sufficient moisture vapor to gradually form cured material on hose walls and at unsealed connections potentially causing an increase in operating pressure and material flow restriction.

Application Types
  • Spray
  • Roof Brush
  • Roll

Properties

Regulatory & Compliance

Applicable Standards
  • Meets or exceeds the requirements of ASTM D6694 Standard Specification Liquid-Applied Silicone Coating.
  • Meets or exceeds the requirements of ASTM C1305 Standard Test Method for Crack Bridging Ability of Liquid Applied Waterproofing Membrane.
  • UL Classified - File #R14571
  • FM Approved
  • Can be used to comply with 2016 Title 24 Part 6 Cool Roof requirements. (White only)
  • CRRC Listed (White only)
  • NSF Protocol P151 - Health Effects from Rainwater Catchment System Components. See listing at www.nsf.org for application and cure instructions for rainwater catchment use. (White only)
  • Texas Department of Insurance
  • Florida Building Code
  • Miami-Dade County Product Control Approved

Technical Details & Test Data

Compatible Substrates

Mod Bit, SPUF, Most Metals, Concrete, Single Ply Membranes (Primer may be required)

Safety & Health

Ponding Water

The chemistry of silicone, which Polyglass Silicone roof coatings are manufactured with, is not adversely affected by ponding water or prolonged rain exposure. Please be advised that good roofing practices, Building Codes and The National Roofing Contractors Association (NRCA) consider ponding water on any roof undesirable and recommend that all roof systems be designed and built to ensure positive drainage (See the NRCA Roofing and Waterproofing Manual and any applicable Code Ordinances).

Packaging & Availability

Packaging Type
Packaging
  • 5 Gallon (18.9 Liters) Pail
  • 55 Gallon (208.1 Liters) Drum

Storage & Handling

Storage & Handling
  • Do not store at temperatures greater than 120ºF.
  • Store 24 hours at room temperature prior to application.
  • Observe normal safeguards for storing and handling of this product prior to and during application.
  • Keep containers covered when not in use.
Shelf Life

12 months from date of manufacture when stored between 35ºF and 75ºF.