Knowde Enhanced TDS
Identification & Functionality
- Additives Included
- Chemical Family
- Fillers Included
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
- Materials Features
Applications & Uses
- Plastics & Elastomers Processing Methods
Properties
- Flame Rating
- Flame Rating
- UL 94 V0
- Filler Content
- 23 - 27
- Physical Properties
- Mechanical Properties
- Thermal Properties
- Flammability
- Processing Parameters
Value | Units | Test Method / Conditions | |
Moisture Content | max. 0.1 | % | — |
Molding Shrinkage - Flow | 0.3 | % | ISO 294-4 |
Molding Shrinkage - Across Flow | 1 | % | ISO 294-4 |
Density | 1.51 | g/cm³ | ISO 1183 |
Value | Units | Test Method / Conditions | |
Tensile Strength | max. 160.0/130.0 | MPa | ISO 527-2 |
Flexural Strength | max. 210.0/155.0 | MPa | ISO 178 |
Elongation at Yield | 2.5/4.5 | % | ISO 527-2 |
Flexural Modulus (23°C) | 8500.0/6500.0 | MPa | ISO 178 |
Charpy Notched Impact Strength (-20°C) | 6 | kJ/m² | ISO 179 |
Charpy Notched Impact Strength (23°C) | 7.0/8.0 | kJ/m² | ISO 179 |
Value | Units | Test Method / Conditions | |
Heat Distortion Temperature B (120°C/h at 455kPa) | 250 | °C | ISO 75/1 |
Heat Distortion Temperature A (120°C/h at 1820kPa) | 250 | °C | ISO 75/1 |
Vicat Softening Tempurature B (50°C/h at 49,05N) | min. 230 | °C | ISO 306 |
Value | Units | Test Method / Conditions | |
Glow Wire Flammability Index - GWFI (2 mm) | 960 | °C | IEC 60695-2-12 |
UL-94 Flammability (1.6 mm) | V0 | - | UL94 |
Value | Units | Test Method / Conditions | |
Drying Temperature | 75 | °C | — |
Mold Temperature | 70 - 120 | °C | — |
Back Pressure | 60 - 100 | bar | — |
Drying Time | 2 - 8 | h | — |
Melt Temperature | 270 - 285 | °C | — |
Peripherical Screw Speed | 250 - 450 | mm/s | — |
Regulatory & Compliance
- Certifications & Compliance
Packaging & Availability
- Country Availability
- Regional Availability