LNP THERMOCOMP RF0039S compound is based on Nylon 6/6 resin containing 15% glass fiber. Added features of this grade include: Flame Retardant, Heat Stabilized.

Polymer Name: Polyamide 66 (PA 66)

Processing Methods: Injection Molding

Fillers Included: Glass Fiber

Additives Included: Flame Retardant, Heat Stabilizer, Mold Release Agent

Flexural Modulus: 5170.0 - 5170.0 MPa

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Fillers Included
Plastics & Elastomers Functions
Technologies

Features & Benefits

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Flame Rating
Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Stress (Break) ¹¹100MPaASTM D638
Tensile Stress (Break) ¹¹98MPaISO 527
Tensile Strain (Break) ¹¹2.9%ISO 527
Tensile Strain (Break) ¹¹3%ASTM D638
Tensile Modulus (at 5 mm/min) ¹¹6060MPaASTM D638
Flexural Stress ¹¹160MPaASTM D790
Flexural Stress ¹¹164MPaISO 178
Flexural Modulus ¹¹6000MPaISO 178
Flexural Modulus ¹¹5170MPaASTM D790
Tensile Modulus (at 1 mm/min) ¹¹6300MPaISO 527
Physical Properties
ValueUnitsTest Method / Conditions
Density ¹¹1.48g/cm³ISO 1183
Density ¹¹1.487g/cm³ASTM D792
Moisture Absorption (at 23°C, 50% RH, 24hrs) ¹¹0.49%ASTM D570
Mold Shrinkage (flow, 24 hrs) ᵍ ¹¹0.89%ISO 294
Mold Shrinkage (flow, 24 hrs) ᵍ ¹¹0.9%ASTM D955
Mold Shrinkage (xflow, 24 hrs) ᵍ ¹¹1.3%ASTM D955
Mold Shrinkage (xflow, 24 hrs) ᵍ ¹¹1.29%ISO 294
Thermal Properties
ValueUnitsTest Method / Conditions
Heat Deflection Temperature (at 0.45 MPa, 3.2 mm, Unannealed) ¹¹251°CASTM D648
Heat Deflection Temperature (at 1.82 MPa, 3.2mm, Unannealed) ¹¹226°CASTM D648
Heat Deflection Temperature/Af (at 1.8 Mpa, Flatw 80*10*4, sp=64mm) ¹¹219°CISO 75/Af
Relative Temperature Index (Electrical) ᵖ ¹¹130°CUL 746B
Relative Temperature Index (Mechanical with impact) ᵖ ¹¹105°CUL 746B
Relative Temperature Index (Mechanical without impact) ᵖ ¹¹115°CUL 746B
Electrical Properties
ValueUnitsTest Method / Conditions
Comparative Tracking Index (UL, PLC) ¹¹3PLC CodeUL 746A
Hot Wire Ignition (PLC 0) ¹¹min. 3mmUL 746A
Hot Wire Ignition (PLC 1) ¹¹min. 1.7mmUL 746A
High Ampere Arc Ignition (PLC 0) ¹¹min. 3mmUL 746A
High Ampere Arc Ignition (PLC 1) ¹¹min. 1.7mmUL 746A
High Voltage Arc Track Rate (PLC) ¹¹1PLC CodeUL 746A
Arc Resistance (Tungsten, PLC) ¹¹7PLC CodeASTM D495
Impact Properties
ValueUnitsTest Method / Conditions
Izod Impact (Unnotched, at 23°C) ¹¹523J/mASTM D4812
Izod Impact (Notched, at 23°C) ¹¹42J/mASTM D256
Instrumented Dart Impact Energy (Peak, at 23°C) ¹¹5JASTM D3763
Multi-Axial Impact ¹¹1JISO 6603
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹38kJ/m²ISO 180/1U
Izod Impact (Notched, 80*10*4, at 23°C) ¹¹5kJ/m²ISO 180/1A
Injection Molding
ValueUnitsTest Method / Conditions
Drying Temperature ⁷80°C
Drying Time ⁷4Hrs
Maximum Moisture Content ⁷0.15 - 0.25%
Melt Temperature ⁷275 - 290°C
Front - Zone 3 Temperature ⁷295 - 305°C
Middle - Zone 2 Temperature ⁷280 - 295°C
Rear - Zone 1 Temperature ⁷265 - 275°C
Mold Temperature ⁷80 - 95°C
Back Pressure ⁷0.2 - 0.3MPa
Screw Speed ⁷30 - 60rpm
Flame Characteristics
ValueUnitsTest Method / Conditions
UL Recognized (94V-0 Flame Class Rating) ᵖmin. 1.7mmUL 94
Note
  • ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
  • ᵖ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card.
  • ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
  • ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
 

Regulatory & Compliance

Certifications & Compliance

Packaging & Availability

Regional Availability
  • Americas
  • Asia
  • Europe
  • North America