Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Chemical Name
- Base Chemicals Functions
- CASE Ingredients Functions
- Fluids & Lubricants Functions
- Industrial Additives Functions
- CAS No.
- 112-72-1
- Technologies
Applications & Uses
- Applications
- Applicable Processes
- Fluids & Lubricants Type
- Fluids & Lubricants End Use
- Industrial Additives End Use
Properties
- Physical Form
- Odor
- Sweet Pungent
- Insoluble in
- Water
- Typical Properties
Value | Units | Test Method / Conditions | |
Molecular Weight (Average) | 214 | g/mol | — |
Total Alcohol Content | min. 98.5 | wt. % | — |
Homolog Distribution - C12OH & lower | max. 2 | wt. % | — |
Homolog Distribution - C14OH | min. 95.5 | wt. % | — |
Homolog Distribution - C16OH & higher | max. 2.6 | wt. % | — |
Density at 60°C | 0.809 | g/mL | — |
Viscosity at 60°C (140°F) | 7.9 | cSt | — |
Vapor Pressure at 20°C (68°F) | max. 0.01 | mmHg | — |
Flammability Upper explosion limit | approx. 3.5 (V) | % | — |
Flammability Lower explosion limit | approx. 0.4 (V) | % | — |
Color | max. 20 | — | EN ISO 6271 |
Water Content | max. 0.1 | wt. % | DIN 51777 |
Acid Number | max. 0.2 | mg KOH/g | EN ISO 2114 |
Saponification Number | max. 1 | mg KOH/g | — |
Vapor Density | 5 – 9 | — | — |
Melting Point | 37 – 39 (99 – 102) | °C (°F) | — |
Iodine Number | max. 0.4 | mg I2/100 mg | — |
Hydroxyl Number | 255 – 264 | mg KOH/g | — |
Flash Point | 143 (289) | °C (°F) | ASTM D 93 |
Carbonyl Content | max. 200 | ppm | — |
Boiling Point | 297 – 301 (567 – 574) | °C (°F) | — |
Auto-ignition Temperature | 254 (490) | °C (°F) | — |
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Viscosity versus Temperature Profile
ALFOL pure cut alcohol viscosity vs temperature
ALFOL blended alcohol viscosity vs temperature
​​​​​​​
- Density versus Temperature Profile
ALFOL pure cut alcohol density vs temperature
ALFOL blended alcohol density vs temperature
​​​​​​​
Storage & Handling
- Handling and Storage
Safe handling advice
Ensure all equipment is electrically grounded before beginning transfer operations.
Storage/Transport pressure
Ambient
Load/Unload temperature
46 - 66 °C (115 - 150 °F)