Seal Bond® 490 Liquid Flashing is a professional grade pourable sealant for use in pitch pans, curb systems, and other liquid flashing applications. It can be used for general roof repairs, roof seams, fasteners, gutters, and other building envelope applications. SB 490 is a 1-Part formulation with self-leveling properties for horizontal applications. SB 490 is based on polyether technology that reacts with moisture to form a strong and flexible seal. SB 490 is suitable for applications in wet, dry, or low temperature climate conditions. The product has excellent weathering and UV resistance and performs in temperatures from -40°F to 200°F.

Product Type: 1K (1 component) Sealant, Solvent free (100% Solids) Sealant

Compatible Substrates & Surfaces: Aluminum, Asphalt, Concrete, Elastomers & Rubbers, Metal, Painted Surfaces, Plastics, Polyvinyl Chloride (PVC), Thermoplastic Polyolefin (TPO), Wood

Cure Method: Moisture Cure

Application Method: Gun

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemistry
Polyether

Features & Benefits

Features
  • 100% solids - no shrinkage
  • Ready to use - no mixing required
  • Low dirt pickup
  • No bubbling or off-gassing in the presence of moisture
  • Safe to use - solvent & Isocyanate Free
  • Ultra-low VOC’s - 17.94 g/L
  • May contribute to LEED V4 EQ Material Resource Credit 4.1 - Adhesives and Sealants
  • Bonds to most common building substrates
  • Remains flexible to absorb expansion and contraction
Product Highlights
  • Does not become dry or brittle
  • Water resistant
  • Permanent elastomeric bond
  • Extended warranties available

Applications & Uses

Application Method
Cure Method
Substrate Compatibility
  • SBS Mod Bit/BUR
  • Aluminum
  • Asphalt
  • Coated Metal
  • PVC / PIB*
  • Cold Rolled Steel
  • TPO with TPO Primer*
  • Concrete
  • Single-Ply Membranes
  • Metal
  • Prepared APP
  • Solar Mounting Systems
  • EPDM*

*Specific substrates may require additional preparation or priming.

Ease of Installation
  • Cures to optimum strength within 7 - 14 days
  • SB 490 can be installed on damp surfaces
  • No Mixing
  • Many compatible substrates
  • Install in dry, wet, or cold temperatures
  • Sealant will not freeze
Product Application

Roofing

Make sure substrate is clean and free of contaminants such as dirt, rust, loose gravel or granules, previously applied caulks or sealants and anything else that may affect proper adhesion and performance. Maintain SB 490 at room temperature before applying to ensure easy gunning and pourability. Test and evaluate to ensure adequate adhesion. When using SB 490 as a curb or pitch pan sealer, follow the form manufacturer’s recommended instructions. Use SB 500 to seal the base and 1” above the pitch pan or curb height of all penetrations to prevent sealer from flowing through the opening. Cut the widest point of tip or nozzle of cartridge and puncture the foil seal. Use caulk gun to pump SB 490 into pitch pan or curb. When using the 2 liter pouch option, remove the cap and pour sealant into pitch pan or curb. If there is remaining sealant in the pouch, squeeze the air out of pouch and reseal for reuse.

Concrete

Prior to application remove any residual contamination by mechanical abrasion, sand blasting or power washing. On green concrete, remove all release agents and loose concrete. Dry all visible and/or standing water.

Metal

Prepare all metal to ensure maximum adhesion. Remove all rust, scale and residue using a wire brush. Remove all contaminants including dirt, oil, rust, old sealants and coatings with an appropriate solvent such as alcohol. Seal Bond recommends that coated substrates be tested for proper adhesion prior to starting a project to determine suitability for use.

Priming

In most applications SB 490 will not require a primer. However, certain substrates may require a primer to ensure a long lasting bond and weatherproof seal. It is the installers responsibility to follow the manufacturers recommendations to determine whether or not a primer is needed in their specific application.

Clean-Up

Clean tools with isopropyl alcohol or mineral spirits. Avoid using water for cleanup.

Limitations
  • Some roofing membranes including APP, EPDM and TPO may require preparation or primer before using SB 490 sealant. Please consult manufacturers recommendations.
  • SB 490 is recommended for flat roof or level applications. For low slope or steep applica- tions, consult Seal Bond Technical Services.
  • Do not use grout, sand, gravel or any other fillers in pitch pan or curb applications.
  • Do not store unused product in direct sunlight, temperatures above 80°F, or high humidity conditions as this will affect the shelf life of the product.
  • Do not use on TPO without TPO primer.
  • Do not use on Hypalon membranes.
  • Smooth APP membranes require preparation of granulated surface of modified bitumen around the penetration.
  • Do not use in areas subject to continuous immersion.
  • Do not prime bonding surfaces with asphalt primer.
  • Test and evaluate all paints before application.

Properties

Typical Properties
ValueUnitsTest Method / Conditions
VOC17.94g/LASTM C1250
Skinover Time (50% RH, 70°F)20.0minASTM C679
Density13.61lb/gal
Hardness54.0ASTM D676 (Shore A)
Peel Strength (ABS Plastic)11.0pliASTM D903
Peel Strength (Acrylic)7.6pliASTM D903
Peel Strength (Aluminum)10.0pliASTM D903
Peel Strength (Mortar)5.6pliASTM D903
Peel Strength (Glass)7.7pliASTM D903
Peel Strength (Pine)5.4pliASTM D903
Peel Strength (PVC)9.7pliASTM D903
Tensile179.0psiASTM D412-06
Elongation at Break105.0%ASTM D412-06
Shrinkage0.0%
Service Temperature-40 to 200°F
Viscosity (1 rpm)235000.0cpsASTM D2196-10
Viscosity (2 rpm)165000.0cpsASTM D2196-10
Viscosity (10 rpm)87500.0cpsASTM D2196-10

Regulatory & Compliance

Standards & Compliance
  • May contribute to LEED V4 EQ Material Resource Credit 4.1 - Adhesives and Sealants
  • Federal Specification TT-S-00230-C Type I, Class B
  • Corps of Engineers CRD-C-541, Type I, Class B
  • Conforms to OTC Rule for Sealants and Caulks Meets requirements of California Regs: CARB, BAAQMD and SCAQMD

Technical Details & Test Data

Test Data

SB 490 values represent data from multiple batches. Values will be refreshed, as necessary, upon data collection from additional campaigns and long-term variability discernment.

Safety & Health

Precautionary Statements
  • Do not use until all instructions and safety precautions have been read and understood.
  • Wear protective gloves, protective clothing and eye protection.
  • Wash contaminated clothing before reuse.
  • Contaminated work clothing should not be allowed out of the workplace.
  • If on skin - Wash exposed body areas with soap and water.
  • If in eyes - Rinse with water, remove contact lenses and continue rinsing. If exposed or concerned get medical advise/attention.

Packaging & Availability

Packaging & Availability
  • 10.1 oz. (300 ml) cartridges - 24 tubes/case, 45 cases/pallet
  • 2 liter pouches - 4 pouches/case, 40 cases/pallet
  • Available in black, gray and white colors.

Storage & Handling

Material Storage and Disposal

Store securely between 60°F - 80°F in unopened container. Dispose of contents/container in accordance with Local/Regional/National/International Regulations.

Shelf Life

The shelf life is 12 months for an unopened container from the date of manufacture.