Knowde Enhanced TDS
Identification & Functionality
- Carrier
- CASE Ingredients Functions
- Technologies
- Product Families
Features & Benefits
- CASE Ingredients Features
- Features
- Protects environment and workers
- Non-staining
- Quick drying
- No separation, typical of traditional emulsion releases
- Excellent release performance for aluminum, metal and plywood forms
- Will not deteriorate or damage surface
- Minimum labor - just spray, brush, roll or dip forms
- Reduces surface preparation and painting costs
- Extensively quality controlled to ensure certified
- VOC and AQMD Compliant
Applications & Uses
- Markets
- Applications
- Coating Type
- Applications
- Forms and other surfaces that are to be made bond free should be cleaned before applying GCC-100. Remove previous build up of concrete, rust, scale and dirt, and repair any holes or fractures from previous use before applying. GCC-100 is ready to use direct from its container. Do not dilute. It may be applied by brush, roller, spray or dipping on forms immediately before pouring concrete. However, because GCC-100 or any other form release agent must be kept off reinforcing steel and any other embedments, spray application must be done with care when forms and steel are already in place. An alternative is to coat forms with GCC-100 just prior to erection of rebar steel. GCC-100 can be effective for up to three weeks before concrete is poured. It is also recommended that forms be treated with GCC-100 between each pour and before long periods of idleness or storage. Coat Uniformly - Leave no Gaps.
Properties
- Typical Properties
Value | Units | Test Method / Conditions | |
Wt/gal | 8.3 | — | — |
Carrier | Water | — | — |
Boiling Point | 212 (100) | °F (°C) | — |
Regulatory & Compliance
- Quality Standards
Technical Details & Test Data
- Specifications
- GCC-100 meets or exceeds the requirements of the Corp of Engineers, Civil Works Construction Guide, CW-0301, section 2.1.2. and 3.1.3. and Bureau of Reclamation Standards, many State Specifications for non-staining form release and VOC regulations including California.
- Coverage
- 500-1000 sq.ft./gal (12.5-25 m2/L) depending on porosity, texture and form material.
Safety & Health
- Health and Safety
- Use only with adequate ventilation.
- If swallowed, do not induce vomiting.
- Use of gloves, goggles and other protective clothing is advised when using this product.
Packaging & Availability
- Packaging and Storage
- GCC-100 is available in 55-gallon drums and 5-gallon pails. Contact SEI Chemical directly to discuss your customized packaging requirements. If properly stored in its original sealed container, one year. Rotate your stock.