Value | Units | Test Method / Conditions | |
Melt Flow Index - MFI (260°C/5 kg) | 50 | g/10 min | ISO 1133 |
Density | 1200 | kg/m3 | ISO 1183 |
Value | Units | Test Method / Conditions | |
Tensile Modulus | 2750 | MPa | ISO 527 |
Yield stress | 65 | MPa | ISO 527 |
Strain at break | 40 | % | ISO 527 |
Flexural modulus, 23° | 2550 | MPa | ISO 178 |
Charpy impact strength (+23°) | N | kJ/m2 | ISO 179/1eU |
Charpy notched impact strength (+23°) | 38 | kJ/m2 | ISO 179/1eA |
Izod Impact notched (1/8 in) | 500 | J/m | ASTM D 256 |
Value | Units | Test Method / Conditions | |
Coefficient of Linear Thermal Expansion (parallel) | 70 | E-6/K | ISO 11359-1/-2 |
Temperature of deflection under load (1.80 Mpa) | 90 | °C | ISO 75-1/-2 |
Thickness tested | 1.7 | mm | — |
Vicat softening temperature | 120 | °C | ISO 306 |
Limiting Oxygen Index | 32 | % | ASTM D 2863 |
Value | Units | Test Method / Conditions | |
Flame rating | V-0 | - | UL 94 |
Value | Units | Test Method / Conditions | |
Water absorption | 0.7 | % | Sim. to ISO 62 |