Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Advantages
- Low Odor
- High film build in one coat
- Meets most VOC regulations
- Corrosion resistant
- Contains no heavy metals
- Ideal for new construction or maintenance applications
- Clean-up with water
Applications & Uses
- Applications
- Application Method
- Uses
Epoxy Acrylic DTM is used to protect exterior and interior structural ferrous and nonferrous steel, institutional walls, and industrial machinery. Epoxy Acrylic DTM, used in conjunction with high build zinc rich primers, is suitable for moderate duty marine applications. EpoxyAcrylic DTM, applied as one part of a three-coat system, is suitable for bridge coating applications.
- Limitations
- Not intended for immersion applications
- Not for below grade applications
- Application Data
Abrasive blast cleaned surfaces shall be tested by the Contractor for soluble salts using a Class Aor B retrieval method as described in Technology Guide 15, “Field Methods for Retrieval and Analysis of Soluble Salts on Steel and Other Nonporous Substrates,” of the “SSPC: The Society of Protective Coatings,” and cleaned so the maximum level of soluble salts does not exceed the 10 micrograms per square centimeter. Areas of abrasive blast cleaned steel shall be tested at the rate of 3 tests for the first 1,000 square feet prepared per day, and one test for each additional 1,000 square feet or portion thereof, at locations selected by the Engineer. When less than 1,000 square feet of surface area is prepared in a shift, at least 2 tests shall be performed. Additionally, the use of a iron phosphate will further enhance corrosion protection.
Applicable Substrates:- Direct to Ferrous or Nonferrous
- Direct to Galvanized
- Properly prepared concrete
Recommended Primers:
920Z KoldGalv - 400 g/l VOC, light marine applications
283P609 Aquapoxy - 83 g/l VOC, ferrous and nonferrous substrates.
Consult your Triangle Coatings representative for other primer recommendations.
Mixing Parameters:
Ratio: [Part A: Part B]
By Weight ...... 9:1
By Volume... 8:1
Sweat-in Time: 30 mins- Applications
HVLP:
- Fluid Tip and Needle: 045"
- Fluid Pressure: 8-10 psi
- Air Cap Pressure: 60 psi
Air Assist Airless:
- Fluid Tip: .017 - .018”
- Fluid Pressure: 800-900 psi
- Air Cap Pressure: 10-15 psi
Airless:
- Fluid Tip: .018 - .021”
- Fluid Pressure: 1,800-2,000 psi
Brush or Rollers: Yes
Thinning: Water
Cleanup: Water
Properties
- Properties
- REQUIRED FILM THICKNESS:
ASTM D1005 Minimum Dried Film 3-4 mils (76-102u)ASTM D4414 Minimum Wet Film .... 8-11 mils (203-280)[2 wet coats are required to obtain the correct DFT]ASTM D523 GLOSS:@60° 55-80 @20° N/A ASTM D3363 PENCIL HARDNESS:2H Pass ASTM D5402 MEK RUBS:50 Double Pass ASTM D2794 IMPACT RESISTANCE:
60 inlb forward, 60 inlb reverse Pass ASTM B117 SALT SPRAY RESISTANCE:5% Salt Spray, 250 hours. Pass ASTM D5894UV CORROSION WEATHERING:ASTM D610 Rusting Pass ASTM D714 Blistering 7 cycles, 300 hours Pass ASTM D4587/D523/D4214 QUv-UVA
500 hours @ 60° 10% Loss 1000 hours @ 60° 20% Loss ASTM D2247/D714 HUMIDITY RESISTANCE:200 hours Pass ASTM D4585 MOISTURE CONDENSATION:100 F, 400 hours. *** Pass ASTM D3359 ADHESION:N/A N/A ASTM D4060 ABRASION RESISTANCE:CS17 wheel, 140 cycles, 1 kg load Pass ASTM D522 FLEXIBILITY:180° bend, 1/8" mandrel. Pass ASTM D3170 CHIP RESISTANCE:Rating N/A ASTM D2485 DRY HEAT RESISTANCE:
N/A N/A ASTM D2243 WATER-BORNE FREEZE THAW:3 cycles Pass
Technical Details & Test Data
- Dry Schedule
DRY SCHEDULE: [at 50% RH and 3.0 mils DFT] 45°F 60°F 85°F Dry to Touch 2hrs 90 mins 60 mins Recoat 2hrs 60 mins 40 mins Dry to Handle 6 hrs 4 hrs 3 hrs Full Cure 14 days 10 days 7 days Critical Recoat Window: After two weeks power wash or mechanically abrade all surfaces.
Safety & Health
- Health and Safety
Warning:
Combustible liquid and vapor. Harmful vapor if inhaled. Vapor may affect the brain or nervous system causing dizziness, headache, or nausea and can cause nose and throat irritation. Keep away from sparks, heat, or open flames. Use with adequate ventilation. Avoid breathing of vapor. Avoid contact with eyes, skin, and clothing. Vash hands thorouafgtehr lusyin g and before eating and smoking. Wear an appropriate, properly fitted respirator (NIOSH/MSHA approved) during and after appliation unless air monitoring demonstrates vapor levels are below applicable limits. Follow respirator manufacturer's directions for use. Keep container closed when not in use. If spillage occurs, absorb and dispose of according to local regulations.
Notice:
Intentional misuse by deliberately concentrating and inhaling the contents may be harmful or fatal. Reports have associated repeated and prolonges occupational overexposure to solvents with permanent brain and nervous system damage.
First Aid:
Should eye contact occur, flush with plenty of water for at least 15 minutes and get medical attention if vision is disturbed. For skin, wash thoroughly with soap and water. If swallowed, seek medical attention immediately. DO NOT induce vomiting.KEEP THIS PRODUCT OUT OF THE REACH OF CHILDREN.
Packaging & Availability
- Color Availability
Factory colors available; refer to Triangle Industrial Products card. Custom Colors Available; minimum order is required. Special costing will be applied.
- Order Code
44 + gloss + color # Individual products are identified by the product series number, followed by a gloss identifier and color number.
- Ex: 44G700 is Epoxy Acrylic DTM, Gloss, White
- Ex: 44G382 is Epoxy Acrylic DTM, Gloss, Safety Yellow
- G=Gloss
- S=Semi-Gloss
- Packaging
Part A:
- 1 gallon cans
- 5 gallon pails (4 gal full)
- 55 gallon drums
Part B:
- 1 pint
- 1 gallon (1/2 full)
- 2 quarts
Storage & Handling
- Pot Life
ASTM D2196 Pot Life: [valid for qtys of1 gallon or more]
50°F 65°F 75°F 85°F 2 days 2 days 1 day 1 day - Shipping and Handling
SHIPPING DESCRIPTION: [cFR 49]
Ground, Air, Vessel ......... Non Regulated Material
Required Label & Marking ............. Not Required
IMDG PACKAGING: .........0...... Not Regulated
IMDG STOWAGE: ............0e0e Not Regulated
UNIFORM FIRE CODE: [CFR 29] ............ CLASS III-B
STORAGE TEMPERATURE. ................. 120° F max
SHELF LIFE: [warranted] .............. 1 YEAR
HMIS RATINGS: ................. H-2;F-0;R-0;PP-B