TriPrime™is a high-solids, solvent-reducible primer for iron and steel that dries quickly. It is intended for use in shop and CEM applications, as well as under all common finishes, including polyurethanes. TriPrime™ is intended for hand-cleaned iron and steel SSPC-SP1, SP2, or SP3, and provides active corrosion inhibition and undercutting protection. It is intended for HVLP and air assisted airless systems, but it can also be used with conventional or airless systems where legal. Most systems require thinning; see the instructions under "Recommended Thinning." Alkyd, silicone alkyd, and acrylic topcoats are all recommended.

Product Type: Primer, Solventless & High Solids Coating

Compatible Substrates & Surfaces: Iron, Metal, Steel

Features: Corrosion Resistant, Fast Drying, High Solids Content

Application Method: Brush, Roll Coater, Spray

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Advantages
  • Compatible with epoxies and similar topcoats that may lift other primers
  • TriPrime (black) may also be used as a finish for wrought iron
  • Excellent corrosion inhibition
  • No critical recoat window
  • Very fast dry

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Uses

Typical applications include construction and industrial equipment, structures, boxes and utility parts.

Limitations

Requires clean steel

Application Data

Surface Preparation:
TriPrime 902P Series primers are designed for use over hand cleaned iron and steel, SSPC-SP1, SP2 or SP3

  • Surface and ambient temperatures must be above 45° F. Recommended maximum surface temperature is 120° F. Temperatures above 95° F may require the use of a “slow” solvent. Contact Triangle for more information.
  • Surfaces must be 100% free of all contaminants except small amounts of fully adherent rust. All loose and scaling material, grease, oils, asphalt, silicones, dirt, dust, chemical contaminants and moisture must be removed.
  • Existing paint should be removed, SSPC-SP2 Completely sound paint may be left, but service life of new system will become that of the existing paint
  • and that will be less than new products alone.
  • Temperatures must be +5° F above dewpoint. Fresh primer must be protected from all moisture until rainproof as per chart above.

REQUIRED THINNING:
Designed for 25 - 30% reduction with 30-003 PCBTF in VOC regulated areas and 34-001 xylene in unregulated areas.
Thinner: 30-003 PCBTF or 34-001 Xylene
Brush or Roller: Thin as required
Airless Spray: Thin as required
Conventional Spray: Thin as required

Applications

This coating may be applied by conventional or airless spray application methods. Apply using crossing pattern.

Technical Details & Test Data

Coverage

Theoretical at 1 mil DFT: 1108 sq ft/gal
Theoretical at 1.5 mils DFT: 738 sq ft/gal
Required Minimum DFT: 2 mils

Dry Schedule
DRY SCHEDULE: [at 50% RH and 2 mils DFT]
  45°F 60°F 75° F 90°F
Tack Dry 45 mins 20 mins 10 mins 30 mins
Dry to Touch 2hrs 45 mins 30 mins | 20 mins
Dry to Handle 5 hrs 3 hrs 2hrs 1.5 hrs
Hard Cure 36 hrs. 30 hrs 24 hrs 22 hrs
Recoat 50 mins 2 0 mins 10 mins 7 mins
*After one week wash clean of all foreign matter. Light
sanding may be necessary if cured coating is subject to
exterior exposure for extended periods.
Tip Selection
High Volume Low Pressure Air Assisted Airless:
Use fluid tip Size 011 - .013
Paint fluid pressure 600 - 650 psi
Air pressure to Quin 75 - 80 psi
Aircap pressure 10 psi maximum
Conventional Air Spray:
Use fluid tip Size 040 - .055
Paint fluid pressure 10 - 15 psi
AirCap Pressure 65 - 75 psi
High Volume Low Pressure Conventional Air:
Use fluid tip Size 040 - .055
Paint fluid pressure 10 - 15 psi
Air pressure to gun 75 - 80 psi
Aircap Pressure 10 psi maximum
Conventional Airless:
Carbide fluid tip size 011-.015 @ 1800 psi.
Electrostatic Equipment:
Consult Trianale representative  
CLEANUP SOLVENT PCBTF or Xylene

Safety & Health

Health and Safety

Caution:
CAUSES IRRITATION. DO NOT INGEST. Avoid contact with eyes and skin. Wash hands thorougly after using and before eating and smoking. If spillage occurs, absorb and dispose of according to local regulations.
First Aid:
Should eye contact occur, flush with plenty of water for at least 15 minutes and get medical attention if vision is disturbed. For skin, wash thoroughly with soap and water. lfswallowed, seek medical attention immediately. DO NOT induce vomiting.
KEEP THIS PRODUCT OUT OF THE REACH OF CHILDREN.

Packaging & Availability

Packaging Type
Order Code

TriPrime products are identified by the product series number, followed by an identifier (P=Primer) and ending in the color number.
TriPrime, Primer, Red Oxide (144-52): 902P109
TriPrime, Primer, Gray (AF-7): 902P609
TriPrime, Primer, Black (B385E): 902P710

Packaging

Four ea. 1 gallon cans per case: 55 lbs
One ea. 5 gallon metal pail: 67 lbs

Storage & Handling

Shipping and Handling
SHIPPING DESCRIPTION: [CFR 49]
Ground, Air, Vessel
Paint, 3, UN1263, PG II
Required Label
FLAMMABLE LIQUID
Required Marking PAINT UN1263
IMDG PACKAGING:  
FLAMMABLE LIQUID, class 3.2, UN1263, II  
IMDG STOWAGE. Category B
UNIFORM FIRE CODE: [CFR 29] CLASS I-B
STORAGE TEMPERATURE 120° F max
SHELF LIFE: [warranted] 1 YEAR
HMIS RATINGS
H -2;F-3;R-0; PP-H