Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Reinforcement Form
- Reinforcement Material
- Composite Materials Functions
- Technologies
- Product Families
Features & Benefits
Applications & Uses
- Markets
- Composites End Use
- What is Grade 2F/14 used for?
- It is used for electro-mechanical applications where the benefits of mechanical toughness and wear resistance are combined with a need for good insulation resistance.
- Typical uses include slot wedges, stator packings, coil formers and operating arms.
Properties
- Color
- Physical Properties
Value | Units | Test Method / Conditions | |
Cross Breaking Strength | 115.0 | MPa | — |
Impact Strength (Notched, Charpy) | 7.0 | kJ/m² | — |
Compressive Strength (Flatwise) | 290.0 | MPa | — |
Compressive Strength (Edgewise) | 215.0 | MPa | — |
Resistance to Compression (Flatwise) | 1.4 | % | — |
Shear Strength (Flatwise) | 80.0 | MPa | — |
Water Absorption (1.6mm Thick) | 50.0 | mg | — |
Water Absorption (3mm Thick) | 60.0 | mg | — |
Water Absorption (6mm Thick) | 80.0 | mg | — |
Water Absorption (12mm Thick) | 90.0 | mg | — |
Electric Strength (Flatwise in Oil, 90°C, 1.6mm Thick) | 9.0 | MV/m | — |
Electric Strength (Flatwise in Oil, 90°C, 3mm Thick) | 7.5 | MV/m | — |
Electric Strength (Flatwise in Oil, 90°C, 6mm Thick) | 6.0 | MV/m | — |
Electric strength (Edgewise in Oil, 90°C) | 35.0 | kV | — |
Insulation Resistance (After Immersion in Water) | 5 × 10¹⁰ | ohms | — |
Loss Tangent (1MHz) | 0.047 | — | — |
Permittivity (1MHz) | 4.8 | — | — |
Relative Density | 1.33 | — | — |
Working Temperature (Continuous) | max. 120 | °C | — |
Working Temperature (Intermittent) | max. 130 | °C | — |
Thermal Classification | Class E | — | — |
Regulatory & Compliance
- Specifications
British Standards Current Standards Recent Standards (Now Obsolete) Sheet BS EN 60893-3-4 Type PF CC 202 BS 2572 Types F4 & F5
Packaging & Availability
- Types Available
Types Availabe Sheets Rods Tubes Other Sections Natural Color Yes No No No