Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Fillers Included
- Polymer Name
- Reinforcement Material
- Abbreviation
- PA 12 GF 30
- Designation
- Polyamide 12 30 % glass fibre
- Type of Polymer
- Thermoplastic
- Trade Name
- CENTROMID 12 GF
- Technologies
Features & Benefits
- Materials Features
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Field of Use
- Automotive industry
- Electrical industry
- Mechanical engineering
- Medical technology
- Plastics industry
- More industries
- Field of Application
- Lever
- Valve parts
Properties
- Color
- Physical Properties
- Mechanical Properties
- Thermal Properties
- Electrical Properties
Value | Units | Test Method / Conditions | |
Density | 1.23 | g/cm³ | ISO 1183 |
Moisture Pick-up till Saturation (in normal climate 23 °C / 50% r.h.) | 0.6 | % | ISO 62 |
Water Absorption Till Saturation (in water at 23°C) | 1.1 | % | ISO 62 |
Value | Units | Test Method / Conditions | |
Charpy Impact Strength (+23 °C) | 80.0 | kJ/m² | ISO 179/1eU |
Charpy Impact Strength - notched (+23 °C) | 20.0 | kJ/m² | ISO 179/1eA |
Tensile Stress at Break [v = 5 mm/min] | 105.0 | MPa | ISO 527-2 |
Nominal Percentage Elongation at Break | 8.0 | % | ISO 527-2 |
Tensile Modulus of Elasticity | 6000.0 | MPa | ISO 527-2 |
Ball Indentation Hardness (value at 30 sec.) | 120.0 | MPa | ISO 2039-1 |
Value | Units | Test Method / Conditions | |
Temperature For Usage in Air (short term) | max. 150 | °C | — |
Temperature For usage in Air (lasting) | max. 105 | °C | — |
Heat Distortion Temperature (HDT A process) | 160.0 | °C | ISO 75-2 |
Coefficient of Linear Expansion (at length, 23 - 60 °C) | 0.2 | 10-4/K | ISO 11359 |
Thermal Conductivity (+23°C) | 0.16 | W/(K · m) | DIN 52612 |
Melting Point (DSC, 10 K/min) | 178.0 | °C | ISO 3146 |
Value | Units | Test Method / Conditions | |
Specific Insulation Resistance | min. 10^11 | Ohm · m | IEC 60093 |
Specific Surface Resistance | min. 10^12 | Ohm | IEC 60093 |
Dielectric Constant (at 1 MHz) | 4.0 | 106 Hz | IEC 60250 |
Dissipation Factor (at 1 MHz) | 0.04 | 106 Hz | IEC 60250 |
Dielectric Strength K20/K20 (in transformer oil) | 35.0 | kV/mm | IEC 60243-1 |
Comparative Tracking Index | 600.0 | — | IEC 60112 |
Regulatory & Compliance
- Food Compliance BfR
- No
- Food Compliance FDA
- No
Packaging & Availability
- Rods
- 20 - 150
- Plates
- 10 - 50
- Stock Lengths
- 1,000 | 3,000
- Width
- 500.0
- Tolerance Length
- 0 - 3
- Tolerance Width
- 1 - 4