company tower banner
Chemical Products Industries, Inc. Company Logo

SW-244-100™ VOC

1 of 1 products in this brand
SW-244-100™ VOC is a high performance, 100% silane water repellent. This unique silane system is designed to penetrate deeply into the substrate and impart a high level of water and chloride ion screening. This provides the substrate with long lasting protection. SW-244-100 VOC is not a coating and as a result will not discolor or change surface appearance.

Product Type: Coating

Features: Alkali Resistant, Breathable, Chemical Resistant, Corrosion Resistant, Fast Curing, Fast Drying, Freeze/Thaw Stability, Good Non-Yellowing Properties, High Performance, Long Term Protection, Low VOC, Water Resistant

Application Area: Bridges

Compatible Substrates & Surfaces: Concrete, Glass, Masonry, Metal, Painted Surfaces, Steel

Application Method: Brush, Roller, Spray

Chemical Family: Silanes

    Knowde Enhanced TDS

    Identification & Functionality

    Chemical Family
    Product Type

    Features & Benefits

    Labeling Claims
    Advantages

    For use on concrete to protect reinforcing steel from corrosion due to the effects of water, deicing salts and other water borne chemicals.
    For use on traffic bearing substrates such as, parking garages, buildings, stadiums, cooling towers, bridge decks and substructures as well as ramps barrier rails and other reinforced concrete structures.
    For use on concrete pavement on highways, and airport runways to reduce scaling due to deicer chemicals.

    Benefits of this product are:

    • 100% Silane
    • Low VOC
    • Meets NCHRP 244 specifications
    • Meets Alberta Transportation specifications
    • High resistance to alkali attack
    • Excellent resistance to water intrusion
    • Breathable system
    • No change in surface appearance

    Chemical Products' state-of-the-art protective treatments have developed a reputation by architects and building professionals as the premier solution for water repellents and sealers. Chemical Products' is dedicated to solving the destructive influence water intrusion and other elements have on building materials. SW-244-100 VOC does not contain exempt solvents such as 1,1,1 trichloroethane that may be hazardous. 

    Applications & Uses

    Application Area
    Application Method
    Applications

    For use on concrete to protect reinforcing steel from corrosion due to the effects of water, deicing salts and other water borne chemicals.
    For use on traffic bearing substrates such as, parking garages, buildings, stadiums, cooling towers, bridge decks and substructures as well as ramps barrier rails and other reinforced concrete structures.
    For use on concrete pavement on highways, and airport runways to reduce scaling due to deicer chemicals.

    Limitations
    Not intended for below-grade waterproofing. Should not be applied if the surface temperature is below 32° F or above 100° F, if rain is expected within two hours following application, or if high winds or other conditions prevent proper application. If rain has preceded the application, the surface should be allowed to dry at least 24 hours. Caution should be taken with specialty coated glass or plastic windows. Check compatibility before application.

    Properties

    Physical Properties
    ValueUnitsTest Method / Conditions
    Active Content100%
    Typical Properties
    ValueUnitsTest Method / Conditions
    Flash Pointmin. 100°F
    Density7.268#/gal
    VOCmax. 400g/l

    Regulatory & Compliance

    Quality Standards

    Technical Details & Test Data

    Test Data

    ALBERTA TRANSPORTATION SPECIFCATIONS

    TYPE 1C, TEST METHOD BT001                        

    Waterproofing after Abrasion >85% Pass
    Alkali Resistance >82% Pass

     

     

    NCHRP #244

    SeriesII >80% Reduction in Water Absorption
    SeriesII >92% Reduction in Chloride Absorption
    SeriesIV 99% Reduction in Chloride Absorption

     

    Installation

    As a standard procedure, fresh concrete should be allowed to dry for 28 days before application. All repointing must be completed and allowed to cure at least 3 days. Concrete repair and replacement must be completed prior to application. Patching materials, caulking, sealing materials, traffic paint must be fully cured before applying SW-244-100 VOC except when using asphaltic sealants and other products which are susceptible to solvent attack. While CPI Water Repellents are compatible with most sealants, specific products should be investigated prior to use.

    All surfaces must be cleaned to remove all traces of dirt, dust, efflorescence, mold, salt, grease, oil, asphalt, laitance, curing compounds, paint, coatings and other contaminants. Acceptable surface cleaning methods include shotblasting, sandblasting, waterblasting and chemical cleaners. Check with your Chemical Products Industries, Inc. representative to verify suitable cleaning methods, products and that the surface preparation is adequate.

    Before applying, it is recommended that preliminary tests be carried out to determine usage and to test the effectiveness of the treatment. A coverage rate of 200-250 square feet per gallon is recommended for dense concrete structures including high rises, parking garages and bridge decks.

    SW-244-100 VOC should be applied by low-pressure (15 to 25 psi) pumping equipment with a wet fan type spray nozzle. Alternate methods include nap roller (1”) or by brush.

    On vertical surfaces, apply in a flooding application from the bottom up so the material runs down 6 to 8 inches below the spray pattern. On horizontal surfaces the liquid material should pond on the surface at least 5 seconds before being absorbed. Coverage rates on horizontal concrete surfaces range from 125 to 400 sq. ft. per gallon. For best results two applications are recommended with the second application applied using a wet on wet technique, i.e., the surface is wet from the first application but not glossy. During application, precautions should be taken to protect the surrounding area from overspray and run off.

    Red Fugitive Dye – available upon request

    Packaging & Availability

    Regional Availability
    • Global
    Availability
    SW-244-100 VOC is available in 5 and 55 gallon drums to approved applicators throughout the United States.

    Storage & Handling

    Precautions
    SW-244-100 VOC is a flammable liquid and should be kept away from heat, sparks, and other sources of ignition. SW-244-100 VOC should be kept closed when not in use and should be stored at temperatures between 0° F and <120° F. Care should be taken to prevent moisture condensation in the container. Please refer to the Material Safety Data Sheet for more detailed information.