Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Product Type
- Technologies
Features & Benefits
- Labeling Claims
Applications & Uses
- Application Method
- Compatible Substrates & Surfaces
- Application Method
- Screen-print
Properties
- Physical Form
- Typical Properties
- Typical Cured Properties
- Consistency
Medium viscosity liquid
Value | Units | Test Method / Conditions | |
Minimum Cure Temperature | 100 | °C | — |
Value | Units | Test Method / Conditions | |
Volume Resistivity (X and Y Axis) | 1x10^12 | Ω - cm | — |
Volume Resistivity (Z Axis) | 0.0001 | Ω - cm | — |
Hydrolytic Stability | Excellent | — | — |
Hardness | -50 | Shore A | — |
Useful Temperature Range | -70 to 260 | ºC | — |
Thermal Stability | Good to 325 | °C | — |
Regulatory & Compliance
- Certifications & Compliance
Safety & Health
- Safety & Handling
- Contains flammable solvents.
- Use with adequate ventilation.
- Keep away from sparks and open flames.
- Avoid prolonged contact with skin and breathing of vapors.
- Wash with soap and water to remove from skin.
Storage & Handling
- Shelf Life
- 6 months at -20°C, Up to 2 weeks at 25°C
- Suggested Handling
Before using 122-44(SP)C should be stirred gently to ensure homogeneity. Further thinning may be accomplished by adding small amounts of toluene, xylene, or 127-05.
- Suggested Handling & Curing
Apply thin film of adhesive to both surfaces to be bonded. Good properties are achieved when cured for 60 minutes at 150°C but end user is advised to experimentally determine temperature and time best suited for individual applications. 122-44(SP)C is not recommended for applications that cannot cure above 100°C. End user is advised to experimentally determine temperature and time best suited for individual applications.
- Storage
Shelf life: up to 2 weeks at 25°C; or 6 months at -20°C. See syringe handling guidelines for recommendations on storage and maintaining homogeneity of material over long-term storage. *122-44(SP)C packaged in syringes must be kept frozen at -40°C