ValueUnitsTest Method / Conditions
Tensile Modulus (1 mm/min)10500 / 5500MPaISO 527
Tensile Stress at Break (5 mm/min)150 / 90MPaISO 527
Tensile Strain at Break (5 mm/min)2.5 / 6.0%ISO 527
Flexural Strength (5 mm/min)230 / 140MPaISO 178
Flexural Modulus (5 mm/min)9000 / 5000MPaISO 178
Charpy Notched Impact Strength (+23 °C)9 / 19kJ/m2ISO 179/1eA
Charpy Notched Impact Strength (-30°C)6 / 7kJ/m2ISO 179/1eA
Charpy Unnotched Impact Strength (+23 °C)62 / 75kJ/m2ISO 179/1eU
Charpy Unnotched Impact Strength (-30 °C)55 / 60kJ/m2ISO 179/1eU
Physical Properties
ValueUnitsTest Method / Conditions
Molding Shrinkage - Parallel (72 hrs, 23°C, 50% RH)0.25 - 0.45%ISO 294-4 / 2577
Molding Shrinkage - Transverse (72 hrs, 23°C, 50% RH)0.75 - 0.95%ISO 294-4 / 2577
Water Absorption (T=23°C / sat.)2%ISO 62
Viscosity Number (96% H2SO4)135ml/gISO 307
Thermal Properties
ValueUnitsTest Method / Conditions
Heat Deflection Temperature - HDT/A (1.80 MPa)210°CISO 75
Heat Deflection Temperature - HDT/B (0.45 MPa)220°CISO 75
Flammability
ValueUnitsTest Method / Conditions
Glow Wire Flammability Index - GWFI (1 - 3 mm)650°CIEC 60695-2-12
Processing Parameters
ValueUnitsTest Method / Conditions
Drying Time (with dew point of dried air < -30 °C)2.0 - 4.0h-
Recommended Melt Temperature250 - 290°C-
Recommended Mold Temperature80 - 100°C-
Drying Temperature75 - 85°C-