MG Chemicals 419C – Fast Drying Acrylic Conformal Coating

419C Acrylic Conformal Coating is an IPC-CC-830B and UL 94 V-0 certified, fast drying, xylene, and toluene free product. This one-part coating provides an excellent finish, is easy to use, and does not require special or costly equipment to apply. It is ideal for high moisture environments and applications requiring easy repair and rework. 419C coating protects electronic circuit against moisture, dirt, dust, and thermal shocks that could corrode, short circuit, or damage the electric component. It insulates against high-voltage arcing, shorts, and static discharges. As well, this coating provides a high dielectric withstand voltage that allows traces to be put closer together which helps with miniaturization.

Product Type: 1K (1 component) Coating, Clearcoat, Conformal Coating

Features: Anti-Static, Corrosion Resistant, Durable, Ease of Handling, Excellent Dielectric Properties, Excellent Dirt Pick-up Resistance, Excellent Salt Spray Resistance, Fast Cure, Fast Drying, Fungus Resistant, Good Smoothness, Moisture Barrier, Thermal Shock Resistant

Compatible Substrates & Surfaces: Metal, Plastics

Application Method: Brush, Dip Coating, Spray

Chemical Family: Acrylics & Acrylates

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family

Features & Benefits

Labeling Claims
Key Attributes
  • Super-fast cure—tack free in about 3 min; dries in 30 min at 65 °C [149 °F]
  • Protects electronics from moisture, corrosion, fungus, and static discharges
  • No Hazardous Air Pollutants—free of toluene or xylene, free of ozone depletion compounds
  • Excellent finish—smooth, homogeneous, and durable crystal clear coat
  • Easy to inspect—fluoresces under UV light
  • Easy rework and repairs—can solder through coat, removable with 435 thinner

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Application Instructions

Spray Equipment
The spray gun recommendations below are based on generic paint guns and may vary by brands. Consult your spray gun manufacturer’s guide.

 

Initial Setting Recommendations

Air Cap HVLP (high volume, low pressure) or LVMP (low volume, medium pressure)
Pressure Inlet: 23 psi,  Air flow: 13.5 SCFM (Standard cubic foot per minute),  Air cap: 10-15 psi
Fluid Tip 0.8–1.3 mm

 

Compatibility

The 419C adheres to most plastics and metals used to house printed circuit assemblies; however, it is not compatible with contaminants like water, oil, or greasy flux residues that may affect adhesion. If contamination is present, first clean the surface to be coated with MG Chemicals 824 Isopropyl alcohol.

Attention! Do not use on thin plastics or plastics where you want to keep original surface. The product contains a controlled amount of solvents designed to chemically etch plastic surfaces to help adhesion.

Properties

Flame Rating
Physical Form
Environmental Properties
ValueUnitsTest Method / Conditions
Cross-Hatch Adhesion5B = 0area removedASTM D3359-2009
Visual Color, Unwashed AreaNo changeASTM D1729-96
Cracking, Unwashed AreaNoneASTM D661-93
Peeling, Unwashed AreaNoneASTM D1729-96
Mechanical Properties
ValueUnitsTest Method / Conditions
Pencil Hardness (ABS)B, softASTM D 3363
Typical Properties
ValueUnitsTest Method / Conditions
FlexibilityExcellentIPC-TM-650 2.4.5.1
Fungus ResistanceExcellentIPC-TM-650 2.6.1.1
SolderabilityExcellent
Theoretical Coverage per US Gallon ⁽ᵃ⁾max. 325000 (max. 50000 )cm2 (in2)
Theoretical Coverage per Litre ⁽ᵃ⁾max. 85000 (max. 1300)cm2 (in2)
Recoat Time2minute
Full Cure (at 22 °C, 72 °F)24hour
Full Cure (at 65 °C , 149 °F)30minute
Thermal Properties
ValueUnitsTest Method / Conditions
CTE (Prior Tg) ⁽ᵃ⁾190 (374)°C(°F)ASTM E 831
Glass Transition Temperature (Tg)46 (115)°C(°F)ASTM E 831
Grease Properties
ValueUnitsTest Method / Conditions
Weather ResistanceExcellent
Flammability
ValueUnitsTest Method / Conditions
Flammability (V-0)94UL registered
Cured Properties
ValueUnitsTest Method / Conditions
Dielectric Withstand Voltagemin. 1500 (min. 1.5)V (kV)per IPC-TM-650
Dielectric Strength at (0.9 mil)1 450 (57.1)V/mil (kV/mm)ASTM D 149
Insulation Resistance (after 24 h)5 x 10¹²ΩIPC-TM-650 Test 2.6.3.4
Temperature Properties
ValueUnitsTest Method / Conditions
Storage Temperature Limits-5 to 40 (23 to 104)°C(°F)
Constant Service Temperature-65 to 125 (-85 to 257)°C(°F)
Uncured Properties
ValueUnitsTest Method / Conditions
OdorEthereal
Boiling Pointmin. 56 (min. 133)°C(°F)
Viscosity (at 23 °C, 73 °F)min. 7 (min. 0.007)cP (Pa·s)Brookfield SP1
Density0.88g/mLMIL-STD-45662A
Solid Content17%
Tack Free3-5minute
Flash Point-17 (1.4)°C(°F)Closed cup
Breakdown Voltage (at 0.9 mil)1 280 (1.28)V (kV)ASTM D 149
Typical Properties Note
a) Estimate based on a coat thickness of 25 μm [1.0 mil] and 65% transfer efficiency.
Cure Instructions

Room temperature cure:

  • Let cure at room temperature for 24 h.

Heat cure:

  • Put in oven at 65 °C [149 °F] for 30 min.
Note
  • See Appendix A for UL 94 V-0 and IPC-CC-830B standards test results.
  • a) Coefficient of Thermal Expansion (CTE) units are in ppm/°C = in/in/°C × 10-6 = unit/unit/°C × 10-6.
Thermal Properties Note
See Appendix A for UL 94 V-0 and IPC-CC-830B standards test results.

Regulatory & Compliance

Certifications & Compliance
Quality Standards
Certified
  • Certified UL 94 V-0 (File # E203094)
  • Externally Qualified to IPC-CC-830B by Pacific Testing Laboratories

Technical Details & Test Data

Test Data
  1. Stir the coating gently but thoroughly.
  2. Spray a test pattern to ensure good flow quality.
  3. At an approximate distance of 20–25 cm (8–10 in), tilt the board 45° from a vertical position and spray a thin and even coat. Use spray-and-release strokes with an even motion to avoid excess paint in one spot. Start and end each stroke off the surface.
  4. Wait 2 min before applying another coat to avoid trapping solvent.
  5. Rotate the board 90° and spray again to ensure good coverage.
  6. Apply other coats until desired thickness is achieved (go to step 3).
  7. Let dry for 2 min at room temperature before heat cure.

 

Touch up by brushing:

  1. Stir the coating gently but thoroughly.
  2. Use a brush apply a small amount to touch up.

Dip coating:
Use a Ford or Zahn cup to monitor the viscosity of the coating as the solvent will evaporate over time.

  1. Hang the PCB on a dipping arm.
  2. Slowly lower the PCB into a tank and leave immersed in the coating for 2 min to allow penetration.
  3. Slowly withdraw the PCB from the tank at an approximate rate of 6"/min.
  4. Let dry to tack free finish before applying additional coats or heat cure.

 

Selective coating: Custom blended solutions are available and have been verified for use with selective coating machines using both non-atomised and film coating applicators. To inquire about a custom solution tailored to your equipment, contact MG Chemicals’ Technical Support for assistance. 

Safety & Health

Health and Safety
Please see the 419C-Liquid Safety Data Sheet (SDS) for further details on transportation, storage, handling, safety guidelines, and regulatory compliance.

Packaging & Availability

Packaging Type
Packaging Information
Cat. No. Packaging Net Volume Net Weight Packaged Weight
419C-340G Aerosol 446 mL [15.0 fl oz] 340 g [11.9 oz] 4.60 kg [10.1 lb] (Case pack of 10)
419C-1L Can 945 mL [1.99 pt] 825 g [1.82 lb] 1.02 kg [2.10 lb] (Case pack of 5)
419C-4L Can 3.78 L [1.00 gal] 3.30 kg [7.28 lb] 4.00 kg [8.82 lb]
419C-20L Can 18.9 L [5.04 gal] 16.5 kg [36.4 lb] Not available

 

Storage & Handling

Shelf Life
5 Years
Storage
Store between -5 and 40 °C [23 and 104 °F] in a dry area, away from sunlight.