Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Fillers Included
- Polymer Name
- Technologies
- Product Families
Features & Benefits
- Materials Features
- Product Overview
- Unfilled Ketron® 1000 PEEK performs to 320°F (160°C)
- Excellent chemical resistance
- Excellent combination of thermal resistance and high compressive strength
- 30% glass fiber filled and 30% carbon fiber filled grades are available
- Injection molded shapes for thin-wall rings, extruded rods and sheets for machined parts, compression molded tubes, rods and sheets for heavier cross-section parts
- Competitive Advantage
Quadrant Ketron® 1000 IM PEEK advanced unfilled polymers, in injection molded shapes, are ideal for machined back-up rings and v-seals. It has excellent chemical resistance and wear resistance across a broad range of operating temperatures and retains mechanical properties to its HDT of 320 ̊F (160 ̊C). Several specific grades are available, some incorporating glass or carbon fibers which significantly increase strength and stiffness with temperature. Other grades contain wear resistant additives that significantly increase the life of machined parts. The performance of Quadrant Ketron® 1000 PEEK in steam and hot water environments, combined with its ductility make it an ideal sealing material - both during installation and in use. Plus, it’s easily machined and has unrivaled chemical resistance compared to all other advanced engineering materials.
Applications & Uses
- Markets
- Plastics & Elastomers End Uses
- Product Applications
Thin-wall Rings, Extruded Rods and Sheets for Machined Parts, Compression Molded Tubes
Properties
- Flame Rating
- Mechanical Properties
- Thermal Properties
- Electrical Properties
- Miscellaneous Properties
Value | Units | Test Method / Conditions | |
Specific Gravity (73˚F) | 1.31 | — | ASTM D792 |
Tensile Strength (73˚F) | 16000 | psi | ASTM D638 |
Tensile Modulus of Elasticity (73˚F) | 600000 | psi | ASTM D638 |
Tensile Elongation (At break, 73˚F) | 25 | % | ASTM D638 |
Flexural Strength (73˚F) | 23000 | psi | ASTM D790 |
Flexural Modulus of Elasticity (73˚F) | 600000 | psi | ASTM D790 |
Compressive Strength (10% Deformation, 73˚F) | 20000 | psi | ASTM D695 |
Compressive Modulus of Elasticity (73˚F) | 425000 | psi | ASTM D695 |
Hardness (Scale as Noted, 73˚F) | M107(R127) | Rockwell | ASTM D785 |
Hardness (Durometer Scale, 73˚F) | D88 | Shore D | ASTM D2240 |
Izod Impact (Notched, 73˚F) | 0.4 | ft-lb/in | ASTM D256 Type “A” |
Coefficient of Friction (Dry vs. Steel, Dynamic) | 0.32 | — | QTM 55007 |
Limiting PV (With 4:1 Safety Factor Applied) | 8500 | ft. lbs./in² min. | QTM 55007 |
Wear Factor (x 10⁻¹⁰) | 375 | in³ -min./ft. lbs. hr | QTM 55010 |
Value | Units | Test Method / Conditions | |
Coefficient of Liner Thermal Expansion (-40˚F to 300˚F) | 2.6 x 10⁻⁵ | in./in./˚F | ASTM E-831 (TMA) |
Heat Deflection Temperature (264 psi) | 320 | °F | ASTM D648 |
Melting Point (Crystalline) - Peak | 644 | °F | ASTM D3418 |
Continuous Service Tempearature in Air (1) | max. 480 | °F | — |
Thermal Conductivity | 1.75 | BTU in./(hr. ft² ˚F) | ASTM E 1530-11 |
Value | Units | Test Method / Conditions | |
Dielectric Strength (Short Term) | 480 | Volts/mil | ASTM D149 |
Surface Resistivity (13) | min. 10 | ohms/square | EOS/ESD S11.11 |
Dielectric Constant (106 Hz) | 3.3 | — | ASTM D150 |
Dissipation Factor (106 Hz) | 0.003 | — | ASTM D150 |
Flammability (3.1 mm) (3) | V-0 | — | UL 94 |
Value | Units | Test Method / Conditions | |
Water Absorption Immersion (24 Hours) | 0.1 | % by wt. | ASTM D570(2) |
Water Absorption Immersion (Saturation) | 0.5 | % by wt. | ASTM D570(2) |
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Material Selection Guide Based on Temperature
Now designers can quickly and easily match the right Advanced Thermoplastic Materials to the right ANSI-Classes, as defined in standard B16.5. This guide is especially helpful when needing to select a wide range of materials like Quadrant Ketron® PEEK, a material with diverse pressure and temperature ranges, ideal for most applications.
- Note
- (1) Data represents Quadrant’s estimated maximum long-term service temperature based on practical field experience.
- (2) Specimens: 1/8” thick x 2” diameter or square.
- (3) Estimated rating based on available data. The UL 94 Test is a laboratory test and does not relate to actual fire hazard.