Ketron® CA30 Polyetheretherketone PEEK is a 30% carbon fiber-reinforced grade that exhibits even higher stiffness, mechanical strength, and creep and wear resistance that Ketron® GF30 PEEK. With a significantly reduced thermal expansion, optimum load carrying capabilities, and high thermal conductivity rates, Ketron® CA30 PEEK components are often favored for their ability to extend part life and rapidly dissipate heat in bearing applications.

Polymer Name: Polyetheretherketone (PEEK)

Physical Form: Plates, Rods

Features: Abrasion Resistant, Chemical Resistant, Corrosion Resistant, Good Compressive Strength, Good Heat Dissipation, Good Thermal Conductivity, High Impact Resistance, High Stiffness, High Strength, High Tolerance, Low Thermal Expansion, Odorless, Wear Resistant

Density: 1400.0 - 1400.0 kg/m³

Tensile Modulus: 9200.0 - 9200.0 MPa

Color: Black

Knowde Enhanced TDS

Identification & Functionality

Fillers Included
Technologies

Features & Benefits

Labeling Claims
Product Overview
  • Excellent chemical resistance
  • Very low moisture absorption
  • Inherently good wear and abrasion resistance
  • Unaffected by continuous exposure to hot water or steam
  • Enhanced compressive strength and stiffness

Ketron® PEEK grades offer chemical and hydrolysis resistance similar to PPS, but can operate at higher temperatures. PEEK 1000 offers steam and wear resistance, while carbon-reinforced PEEK provides excellent wear capabilities. Our latest grade, PEEK HPV, offers outstanding bearing performance. PEEK can be used continuously to 480°F (250°C) and in hot water or steam without permanent loss in physical properties. For hostile environments, PEEK is a high strength alternative to fluoropolymers. PEEK carries a V-O flammability rating and exhibits very low smoke and toxic gas emission when exposed to flame.

Applications & Uses

Product Applications
  • Pump Wear Rings - Ketron® CA30 PEEK improves centrifugal pump efficiency by permitting closer running tolerances and eliminating corrosion, galling and wear problems (Prior material: Bronze).
  • Bearings, Rollers, Gears

Properties

Color
Flame Rating
Physical Form
Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Strength144MPaISO 527-1/-2 (7)
Tensile Strain (Elongation) at Break3.5%ISO 527-1/-2 (7)
Tensile Modulus of Elasticity9200MPaISO 527-1/-2 (9)
Shear Strength103MPaASTM D732
Compressive Stress (1 / 2 / 5 % Nominal Strain)69/125/170MPaISO 604 (10)
Charpy Impact Strength (Unnotched)50kJ/m²ISO 179-1/1eU
Charpy Impact Strength (Notched)5kJ/m²ISO 179-1/1eA
Flexural Strength220MPaISO 178 (12)
Hardness (14)102Rockwell MISO 2039-2
Thermal Properties
ValueUnitsTest Method / Conditions
Melting Temperature (DSC, 10°C (50°F) / min)340°CISO 11357-1/-3
Thermal Conductivity (23°C)0.92W/(K.m)
Coefficient of Linear Thermal Expansion (23 - 60°C)25µm/(m.K)
Coefficient of Linear Thermal Expansion (23 - 100°C)25µm/(m.K)
Coefficient of Linear Thermal Expansion (min. 150°C)55µm/(m.K)
Heat Deflection Temperature (Method A: 1.8 MPa (264 PSI))260°CISO 75-1/-2
Continuous Allowable Service Temperature in Air (20.000 hrs) (3)250°C
Minimum Service Temperature (4)-20°C
Flammability (3 mm) (5)V-0UL 94
Flammability (Oxygen Index)40%ISO 4589-1/-2
Electrical Properties
ValueUnitsTest Method / Conditions
Surface Resistivity10E4 - 10E6Ohm/sq.ANSI/ESD STM 11.11
Miscellaneous Properties
ValueUnitsTest Method / Conditions
Density1.4g/cm³ISO 1183-1
Water Absorption (After 24h Immersion in Water of 23°C)0.05%ISO 62 (16)
Water Absorption (At Saturation in Water of 23 °C)0.35%
Wear Rate2µm/kmISO 7148-2 (18)
Dynamic Coefficient of Friction0.2 - 0.3ISO 7148-2 (18)

Regulatory & Compliance

Certifications & Compliance
Chemical Inventories

Technical Details & Test Data

Engineering Notes

The stiffness of all PEEK grades drops off significantly and expansion rate increases above its glass transition temperature (Tg) of 300°F (150°C). A material like Torlon* PAI would be better suited for close tolerance bearings or seals operating at temperatures higher than 300°F (150°C)

Note
  • Thermal Properties -  The figures given for these properties are for the most part derived from raw material supplier data and other publications.
  • (2) Values for this property are only given here for amorphous materials and for materials that do not show a melting temperature (PBI, PAI & PI). DMA settings, oscillation amplitude of 0.20 mm; a frequency of 1 Hz; heating rate of 2°C/min
  • (3) Temperature resistance over a period of min. 20,000 hours. After this period of time, there is a decrease in tensile strength – measured at 23 °C – of about 50 % as compared with the original value. The temperature value given here is thus based on the thermal-oxidative degradation which takes place and causes a reduction in properties. Note, however, that the maximum allowable service temperature depends in many cases essentially on the duration and the magnitude of the mechanical stresses to which the material is subjected.
  • (4) Impact strength decreasing with decreasing temperature, the minimum allowable service temperature is practically mainly determined by the extent to which the material is subjected to impact. The value given here is based on unfavorable impact conditions and may consequently not be considered as being the absolute practical limit.
  • (5) These estimated ratings, derived from raw material supplier data and other publications, are not intended to reflect hazards presented by the material under actual fire conditions. There is no ‘UL File Number’ available for these stock shapes.
  • Mechanical Properties -  Most of the figures given for the mechanical properties are average values of tests run on dry test specimens machined out of rods 40-60 mm when available, else out of plate 10-20mm. All tests are done at room temperature (23° / 73°F)
  • (7) Test speed: either 5 mm/min or 50 mm/min [chosen acc. to ISO 10350-1 as a function of the ductile behavior of the material (tough or brittle)] using type 1B tensile bars
  • (8) Test speed: either 0.2"/min or 2"/min or [chosen as a function of the ductile behavior of the material (brittle or tough)] using Type 1 tensile bars
  • (9) Test speed: 1 mm/min, using type 1B tensile bars
  • (10) Test specimens: cylinders Ø 8 mm x 16 mm, test speed 1 mm/min
  • (11) Test specimens: cylinders Ø 0.5" x 1", or square 0.5" x 1", test speed 0.05"/min
  • (12) Test specimens: bars 4 mm (thickness) x 10 mm x 80 mm; test speed: 2 mm/min; span: 64 mm.
  • (13) Test specimens: bars 0.25" (thickness) x 0.5" x 5"; test speed: 0.11"/min; span: 4"
  • (14) Measured on 10 mm, 0.4" thick test specimens.
  • (15) Electrode configuration: Ø 25 / Ø 75 mm coaxial cylinders; in transformer oil according to IEC 60296 ; 1 mm thick test specimens.
  • (16) Measured on disks Ø 50 mm x 3 mm.
  • (17) Measured on 1/8" thick x 2" diameter or square
  • (18) Test procedure similar to Test Method A: “Pin-on-disk” as described in ISO 7148-2, Load 3MPa, sliding velocity= 0,33 m/s, mating plate steel Ra= 0.7-0.9 μm, tested at 23°C, 50%RH.
  • (19) Test using journal bearing system, 200 hrs, 118 ft/min, 42 PSI, steel shaft roughness 16±2 RMS micro inches with Hardness Brinell of 180-200
  • (20) Test using Plastic Thrust Washer rotating against steel, 20 ft/min and 250 PSI, Stationary steel washer roughness 16±2 RMS micro inches with Rockwell C 20-24
  • (21) Test using Plastic Thrust Washer rotating against steel, Step by step increase pressure, Test ends when plastic begins to deform or if temperature increases to 300°F.