- APPLICATION CONDITIONS
Ambient and surface temperature should be similar and above 10°C (50°F). Warming surfaces and surrounding air is a good option when working in colder temperatures. Relative humidity should be below 85% and dew point is maintained 3°C (5°F) above substrate temperature for the duration of the application. Always protect the area from contaminates and direct sunlight.
- APPLICATION INSTRUCTIONS (23°C / 73°F)
Apply using one or two coats by brush or roller after proper surface preparation. Grit-blasting using medium to fine grit creating a minimum profile of 2 mil (50 microns). Be aware using other forms of surface preparations such as grinding may reduce adhesion and should be tested individually to assure adhesion strength.
Working Time: 2 hours
Dry Times: 12 hrs
DFT: 125 micron (.005”)
Recoat Time: Min 2 hrs, max 5 days, free from contaminants
Clean up: Non oil based solvent such as Ethyl AcetateMIXING INSTRUCTIONS:
Mechanical mix before use
Appearance: Amber clear
Induction time: 5 minutes
Mix Ratio by weight: 100A: 44.5B
Do not dilute
Properties
- Typical Properties
Value | Units | Test Method / Conditions | |
Mixed Viscosity | 400.0 | cps | — |
Flash Point | None | — | — |
Solids content | 100.0 | % | — |
Theoretical coverage (125 micron/kg (33.4sqft (.005”/lb)) | 6.8 | sqm | — |
Required DFT | 125 (.005) | micron(”) | — |
Packaging & Availability
- Available Kit Sizes
900 g, 3.5 kg, 21 kg
Storage & Handling
- Storage
Storage: Under 27°C (80°F) away from sunlight
Shelf life: +1 year, unopened