Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Product Highlights
- Two-part, translucent, pourable silicone system
- Offers a high tear strength, good physical properties
- 10:1 Mix Ratio (Part A:B)
Applications & Uses
- Applications
- Application Area
- Applications
- For applications requiring low outgassing and minimal volatile condensables under extreme operating conditions
- To provide protection of electric components and assemblies against shock, vibration, moisture, dust, chemicals and other environmental hazards
- Ideal for use in potting connectors, cable harness breakouts, molded high-voltage terminals, seals and gaskets due to a high tear strength
- Instructions for Use
Mixing
Thoroughly mix Part A and Part B, in a 10:1 mix ratio by weight prior to use.
Vacuum Deaeration
Remove air entrapped during mixing by common vacuum deaeration procedure, observing all applicable safety precautions. Slowly apply full vacuum to a container rated for use and at least four times the volume of the material being deaerated. Hold vacuum until bulk deaeration is complete.
Inhibition Concerns
Cures in contact with most materials common to electronic assembles. Exceptions include butyl and chlorinated rubbers, some RTV silicones and unreacted residues of some curing agents. Units being encapsulated or potted should be clean and free of surface contaminates. Containers and dispensers being used should also be clean and dry. Cure inhibition can usually be prevented by washing all containers with solvent or volatizing the contaminant by heating.
Note: Some bonding applications may require the use of a primer. NuSil Technology CF1-135 silicone primer is recommended.
Adjustable Cure
Schedule Product cures at a wide range of cure times and temperatures to accommodate different production needs.
Properties
- Color
- Appearance
- Translucent
- Typical Properties
- Cured Properties
Value | Units | Test Method / Conditions | |
Viscosity | 90,000 (90,000 ) | cP (Mpa*s) | — |
Durometer Type A | 35.0 | — | — |
Elongat ion | 400.0 | % | — |
Mix Rat io | 0.417361111 | — | — |
Specific Gravity | 1.1 | — | — |
Tack Free Time | 15.0 | hours | — |
Tear | 75 (13.23 ) | ppi (kN/m) | — |
Tensile | 925 (6.38 ) | psi (MPa) | — |
Work Time | 3.0 | hours | — |
Value | Units | Test Method / Conditions | |
Cure System | Platinum | — | — |
Cure at 150 °C | 15.0 | minutes | — |
Packaging & Availability
- Country Availability
- Regional Availability