Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Reinforcement Form
- Reinforcement Material
- Composite Materials Functions
- Fibre
- Carbon
- Fibre Type
- TR30S
- Technologies
Features & Benefits
- Labeling Claims
- Materials Features
- Benefits
• Cure temperature as low as 65°C
• High service temperatures - as high as 125°C (DSC) after postcure
• Out life at 20°C: up to 30 days
• Storage life at -18°C: 12 months
• Solvent-free
Applications & Uses
- Applications
- Composites Processing Methods
- Applications
- Automotive
- Motorsport
- Marine
- Defense
- Processing Methods
- Vacuum bag
- Autoclave
- Pressure molding
- Tube rolling
- Pressure bag
Properties
- Physical Form
- Mechanical Properties
- Typical Properties
Value | Units | Test Method / Conditions | |
Fabric Weave Style | Twill 2/2 | - | - |
Thermogravimetry (DSC) | 120 | °C | - |
Fabric Weight | 204 | g/m2 | - |
Resin Content | 42 | % | - |
Tensile Strength | 823.7 | MPa | ASTM D3039 |
Tensile Modulus | 60.3 | GPa | ASTM D3039 |
Flexural Strength | 998.7 | MPa | ASTM D790 |
Flexural Modulus | 65.8 | GPa | ASTM D790 |
Value | Units | Test Method / Conditions | |
Cure Temperature | 65–120 | °C | - |
Technical Details & Test Data
- Cure Cyle
Initial cure 65°C at a ramp rate of up to 2°C and maintain for 16 hours, process under vacuum, pressing or autoclave. Post cure (where required for high Tg) 1 hour dwell at 120°C - maximum ramp rate of 20°C per hour. Resulting Tg: 125°C (DSC).
Alternative cure cycles and resulting Tg:
Cure (°C) Time (hrs) Tg(°C) 65 16 65 120 1 125