LNP LUBRICOMP UL002S compound is based on Polyphthalamide (PPA) resin containing 10% PTFE. Added features of this grade include: Heat Stabilized, Wear Resistant.

Polymer Name: Polyphthalamide (PPA)

Processing Methods: Injection Molding

Fillers Included: PTFE

Additives Included: Heat Stabilizer, Lubricant (PTFE)

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Fillers Included
Plastics & Elastomers Functions
Technologies

Features & Benefits

Wear and Friction Solutions High Temperature Materials

Design engineer look to replace metal parts and components with thermoplastics whenever possible. Not only can they be produced more cost-effectively, they offer greater design flexibility, weigh less and resist corrosion. The availability of high temperature resins like PEEK, PPS, PPA and PEI can stretch the use of thermoplastic even further.

If you can’t stand the heat… internally lubricated compounds:  While auto under-the-hood and industrial machinery might be the first to come to mind, high temperature application are not always driven by hot operating environment. Some application that may never see elevated use temperatures have to survive a hot manufacturing environment (lead-free solder, paint ovens). High temperature generally feature good chemical resistance as well.

Internally lubricated compounds:

The addition of an internal lubricant to a thermoplastic material can improve the wear resistance and can reduce the coefficient of friction in plastic parts. Traditional lubricants like PTFE and PTFE/Si blends are common. Compounds made with high temperature resins can provide wear performance comparable with externally lubricated metal parts.

 

Product Features
  • HDT: 110°C,
  • Good balance of cost and performance
  • Low wear and COF

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Flame Rating
Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Stress (Yield, Type I, 5 mm/min) ¹¹60MPaASTM D638
Tensile Stress (Break, Type I, 5 mm/min) ¹¹60MPaASTM D638
Tensile Strain (Yield, Type I, 5 mm/min) ¹¹2.2%ASTM D638
Tensile Strain (Break, Type I, 5 mm/min) ¹¹2.2%ASTM D638
Tensile Modulus (at 50 mm/min) ¹¹3170MPaASTM D638
Flexural Stress (Yield, 1.3 mm/min, 50 mm span) ¹¹105MPaASTM D790
Flexural Stress (Break, 1.3 mm/min, 50 mm span) ¹¹105MPaASTM D790
Flexural Modulus (at 1.3 mm/min, 50 mm span) ¹¹2980MPaASTM D790
Tensile Stress (Yield, 5 mm/min) ¹¹58MPaISO 527
Tensile Stress (Break, 5 mm/min) ¹¹60MPaISO 527
Tensile Strain (Yield, 5 mm/min) ¹¹2.1%ISO 527
Tensile Strain (Break, 5 mm/min) ¹¹2.2%ISO 527
Tensile Modulus (at 1 mm/min) ¹¹3210MPaISO 527
Physical Properties
ValueUnitsTest Method / Conditions
Density ¹¹1.26g/cm³ISO 1183
Density ¹¹1.25g/cm³ASTM D792
Moisture Absorption (at 23°C, 50% RH, 24hrs) ¹¹0.47%ASTM D570
Mold Shrinkage (flow, 24 hrs) ᵍ ¹¹0.9 - 2%ASTM D955
Mold Shrinkage (xflow, 24 hrs) ᵍ ¹¹0.7 - 0.9%ASTM D955
Wear Factor Washer ¹¹2010^-10 in^5-min/ft-lb-hrASTM D3702 Modified: Manual
Wear Factor Ring ¹¹-110^-10 in^5-min/ft-lb-hrASTM D3702 Modified: Manual
Dynamic COF ¹¹0.26ASTM D3702 Modified: Manual
Static COF ¹¹0.16ASTM D3702 Modified: Manual
Moisture Absorption (at 23°C, 50% RH) ¹¹0.73%ISO 62
Impact Properties
ValueUnitsTest Method / Conditions
Izod Impact (Unnotched, at 23°C) ¹¹453J/mASTM D4812
Izod Impact (Notched, at 23°C) ¹¹26J/mASTM D256
Instrumented Dart Impact Total Energy (at 23°C) ¹¹2JASTM D3763
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹27kJ/m²ISO 180/1U
Izod Impact (Notched, 80*10*4, at 23°C) ¹¹2kJ/m²ISO 180/1A
Injection Molding
ValueUnitsTest Method / Conditions
Drying Temperature ⁷120°C
Drying Time ⁷4Hrs
Maximum Moisture Content ⁷0.15%
Melt Temperature ⁷315 - 330°C
Front - Zone 3 Temperature ⁷325 - 340°C
Middle - Zone 2 Temperature ⁷315 - 325°C
Rear - Zone 1 Temperature ⁷310 - 320°C
Mold Temperature ⁷150 - 170°C
Back Pressure ⁷0.2 - 0.3MPa
Screw Speed ⁷30 - 60rpm
Flame Characteristics
ValueUnitsTest Method / Conditions
UL Recognized (94V-2 Flame Class Rating) ᵖ1.5mmUL 94
Note
  • ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
  • ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
  • ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
  • ᵖ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card.
 

Regulatory & Compliance

Certifications & Compliance

Packaging & Availability

Regional Availability
  • Americas
  • Asia
  • Europe
  • North America