company tower banner
SABIC's Specialties Business Company Logo

LNP™ STAT-KON™ Compound EX03319C

1 of 208 products in this brand
SABIC's Specialties Business LNP STAT-KON EX03319C compound is based on Polyetherimide (PEI) resin containing 20% carbon fiber. Added features of this grade include: LNP Clean Compounding Technology, Low Non-Volatile Residue (NVR), Electrically Conductive This product does not contain PFAS intentionally added during SHPP’s manufacturing process and are not expected to contain unintentional PFAS impurities. Each user is responsible for evaluating the presence of unintentional PFAS impurities.

Polymer Name: Polyether Imide (PEI)

Processing Methods: Injection Molding

Fillers Included: Carbon Fiber

Additives Included: Mold Release Agent

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Additives Included
Fillers Included
Plastics & Elastomers Functions
Technologies

Features & Benefits

Labeling Claims

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Stress (Break, Type I, 5 mm/min) ¹¹224MPaASTM D638
Tensile Strain (Break, Type I, 5 mm/min) ¹¹2.3%ASTM D638
Tensile Modulus (at 50 mm/min) ¹¹16960MPaASTM D638
Flexural Stress (Break, 1.3 mm/min, 50 mm span) ¹¹233MPaASTM D790
Flexural Modulus (at 1.3 mm/min, 50 mm span) ¹¹11600MPaASTM D790
Physical Properties
ValueUnitsTest Method / Conditions
Density ¹¹1.351g/cm³ASTM D792
Moisture Absorption (at 23°C, 50% RH, 24hrs) ¹¹0.2%ASTM D570
Mold Shrinkage (flow, 24 hrs) ᵍ ¹¹0.05 - 0.15%ASTM D955
Mold Shrinkage (xflow, 24 hrs) ᵍ ¹¹0.3 - 0.45%ASTM D955
Thermal Properties
ValueUnitsTest Method / Conditions
Heat Deflection Temperature (at 1.82 MPa, 3.2mm, Unannealed) ¹¹205°CASTM D648
Electrical Properties
ValueUnitsTest Method / Conditions
Volume Resistivity ᵈ ¹¹5000 - 5000000Ω.cmASTM D257
Surface Resistivity ᵈ ¹¹5000 - 500000ΩASTM D257
Static Decay (at 5000V to max. 50V) ¹¹max. 0.1SecondsFTMS101B
Impact Properties
ValueUnitsTest Method / Conditions
Izod Impact (Unnotched, at 23°C) ¹¹354J/mASTM D4812
Izod Impact (Notched, at 23°C) ¹¹48J/mASTM D256
Charpy Impact (at 23°C, V-notch Edgew 80*10*4 sp=62mm) ¹¹4kJ/m²ISO 179/1eA
Charpy Impact (at 23°C, Unnotch Edgew 80*10*4 sp=62mm) ¹¹22kJ/m²ISO 179/1eU
Injection Molding
ValueUnitsTest Method / Conditions
Drying Temperature ⁷150°C
Drying Time ⁷4 - 6Hrs
Maximum Moisture Content ⁷0.02%
Melt Temperature ⁷360 - 400°C
Rear - Zone 1 Temperature ⁷360 - 380°C
Middle - Zone 2 Temperature ⁷370 - 390°C
Front - Zone 3 Temperature ⁷380 - 400°C
Nozzle Temperature ⁷390 - 400°C
Mold Temperature ⁷140 - 180°C
Back Pressure ⁷0.3 - 0.7MPa
Screw Speed (Circumferential speed) ⁷0.2 - 0.3m/s
Vent Depth ⁷0.025 - 0.076mm
Note
  • ᵈ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding. Do NOT mix NORYL GTX* resin with other grades of NORYL* resins. Polystyrene and acrylic regrind are effective purging Materials. Use temperature range appropriate for particular purging resin. Regrind must also be dried. Maximum 25% regrind. Dry at recommended temperatures and times for optimum performance. Overdrying can cause loss of physical properties and/or create appearance defects. Do not exceed recommended basic drying time and temperature above or:\n4-8 hrs at 95°C (200°F), 10 hrs max\n6-12 hrs at 80°C (175°F), 16 hrs max\n8-16 hrs at 65°C (150°F), 24 hrs max\nAVOID air circulating tray ovens. Moisture levels in heated ambient air can exceed moisture level in the resin itself, causing moisture ABSORPTION not drying. Avoid melt temperature in excess of 300°C (575°F) and residence times over 6-8 minutes (may affect properties and/or appearance). Nozzle temperature controls assist in elimination of drool premature freeze-off. Shot sizes in excess of 50% barrel capacity can lead to difficulties in providing a consistent, homogenous plastic melt.
  • ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
  • ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
  • ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
 

Packaging & Availability

Regional Availability
  • Americas
  • Asia
  • Europe
  • North America