company tower banner
SABIC's Specialties Business Company Logo

LNP™ THERMOCOMP™ Compound LF002XXP-WT02005

1 of 486 products in this brand
LNP THERMOCOMP LF002XXP-WT02005 compound is based on Polyetheretherketone (PEEK) resin containing 10% glass fiber. Added features of this grade include: Custom Color.

Polymer Name: Polyetheretherketone (PEEK)

Processing Methods: Injection Molding

Fillers Included: Glass Fiber

Flexural Modulus: 7500.0 - 7500.0 MPa

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Fillers Included
Plastics & Elastomers Functions
Technologies

Features & Benefits

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Color
Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Stress (Break, 5 mm/min) ¹¹110MPaISO 527
Tensile Strain (Yield, 5 mm/min) ¹¹2.6%ISO 527
Tensile Modulus (at 1 mm/min) ¹¹8550MPaISO 527
Flexural Stress (Break, 2 mm/min) ¹¹170MPaISO 178
Flexural Modulus (at 2 mm/min) ¹¹7500MPaISO 178
Physical Properties
ValueUnitsTest Method / Conditions
Mold Shrinkage (flow) ᵍ ¹¹0.4 - 0.6%SABIC method
Density ¹¹1.88g/cm³ISO 1183
Water Absorption (at 23°C, 24hrs) ¹¹0.04%ISO 62-1
Thermal Properties
ValueUnitsTest Method / Conditions
Coefficient of Thermal Expansion (at 23°C to 60°C, flow) ¹¹0.0000281/°CISO 11359-2
Coefficient of Thermal Expansion (at 23°C to 60°C, xflow) ¹¹0.0000421/°CISO 11359-2
Heat Deflection Temperature/Af (at 1.8 Mpa, Flatw 80*10*4, sp=64mm) ¹¹179°CISO 75/Af
Impact Properties
ValueUnitsTest Method / Conditions
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹30kJ/m²ISO 180/1U
Izod Impact (Notched, 80*10*4, at 23°C) ¹¹5kJ/m²ISO 180/1A
Injection Molding
ValueUnitsTest Method / Conditions
Drying Temperature ⁷120 - 150°C-
Drying Time ⁷4Hrs-
Maximum Moisture Content ⁷0.1%-
Melt Temperature ⁷380 - 390°C-
Front - Zone 3 Temperature ⁷380 - 395°C-
Middle - Zone 2 Temperature ⁷365 - 375°C-
Rear - Zone 1 Temperature ⁷350 - 360°C-
Mold Temperature ⁷140 - 165°C-
Back Pressure ⁷0.3 - 0.7MPa-
Screw Speed ⁷60 - 100rpm-
Note
  • ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
  • ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
  • ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
 