company tower banner
SACO AEI Polymers Company Logo

PEXIDAN® SX409NT

1 of 49 products in this brand
PEXIDAN® SX409NT pre-grafted base is mixed with a crosslinking catalyst masterbatch CM401 in the ratio 95:5. The SX409NT:CM401 system has been developed specifically for cables operating up to 36kV. The graft compound contains a non-staining stabilizer and an effective tree retarder, giving outstanding long term retention of dielectric strength. This compound is typically used in conjunction with crosslinkable semi-conducting material for conductor and insulation shields. Crosslinking is obtained by exposure to moist or hot water immersion only.

Polymer Name: Crosslinked Polyethylene (XLPE / PEX)

Processing Methods: Extrusion

End Uses: Cables, Medium Voltage Insulation, Wires

Density: 928.0 - 928.0 kg/m³

Technical Data Sheet

Similar Products

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Additives Included
Plastics & Elastomers Functions
Technologies

Features & Benefits

Key Characteristics

Silane crosslinkable polyethylene for medium voltage power cable insulation

Applications & Uses

Cure Method
Plastics & Elastomers End Uses
Plastics & Elastomers Processing Methods

Properties

Physical Form
Appearance
Pellets
Mechanical Properties
ValueUnitsTest Method / Conditions
Elongation at Break350%IEC 60811-501
Elongation at Break (After Thermal Aging: 7 days at 135ºC)-2% VariationIEC 60811-401
Tensile Strength (at Break)18N/mm²IEC 60811-501
Tensile Strength at Break (After Thermal Aging: 7 days at 135ºC)4%IEC 60811-401
Physical Properties
ValueUnitsTest Method / Conditions
Density0.928g/cm³BS EN ISO 1183-3
Melt Flow Rate (at 190°C / 21.6 kg)0.6-0.9g/10 minInternal Method
Electrical Properties
ValueUnitsTest Method / Conditions
Dielectric Strength (at 20°C)21k/VmmIEC 80243
Permittivity (50Hz at 23°C)2.5IEC 60250
Power Factor (50Hz at 23°C)0.0004IEC 60250
Volume Resistivity (at 20°C)min. 1 x 10¹⁶Ohm.cmBS EN 50395
Thermo-Mechanical Properties
ValueUnitsTest Method / Conditions
Cold Bend (at -70°C)PassNo CracksIEC 60811-504
Insulation Thickness: 15mmmin. 280HoursIEC 60811-507
Insulation Thickness: 3-6mm6-24HoursIEC 60811-507
Insulation Thickness: 8mmmin. 190HoursIEC 60811-507
Elongation Under Load (20N/cm² at 200°C)(Cure Assessment by Hot Set Test: Forced Cured at 80°C in Water)min. 100%

Technical Details & Test Data

Processing

Extruder - Most modern thermoplastic extruders will process this compound, particularly if a screw suitable for polyethylene extrusion is available.

Extruder Temperature Conditions - It is important that the melt temperature is not allowed to increase above 190°C. As a guide the following temperature profile is recommended:

  Zone #1 Zone #2 Zone #3 Zone #4 Head Die
Celsius 150°C 160°C 170°C 180°C 185°C 190°C
Fahrenheit 302°F 320°F 338°F 356°F 365°F 374°F

This profile will vary slightly depending on extruder type, head design and output. Initial purging of the extruder should be performed without the addition of catalyst masterbatch to reduce risks of precuring.

Screw Water Temperature: Not mandatory, if present we recommend 60-70°C

Recommended Screen Pack: 30, 100, 30 (mesh aperture per linear inch) or 600,150, 600 micron

Head & Tool Design - The head and tools should be so designed as to allow streamlined flow without the possibility of stagnation of material (where pre-curing could take place). To obtain the optimum in physical properties in the case of tubing tools, it is generally recommended that a draw down ratio not greater than 3.5 is used.

Crosslinking or Cure: A fast cure can be obtained either by immersion in hot water or exposure to low pressure steam at a temperature up to 70°C.

Catalyst & Color Masterbatches - CM401 is normally added at 5% to 95% of SX409NT graft. Addition of approved color masterbatches, including black, up to a maximum of 1%, has no detrimental effect on the properties or crosslinking capability. It is recommended that all masterbatches, including those containing the catalyst, should be thoroughly dried at 60°C for 8 hours or at 80°C for 4 hours.

Packaging & Availability

Packaging Type
Packaging

the following possibilities are available:

  • Moisture resistant sacks containing 25kg.
  • Boxes with a moisture resistant heat sealed liner containing approximately 500kg

Storage & Handling

Storage & Shelf Life

A period of at least 6 months from date of manufacture can normally be expected. The following storage conditions are recommended:

  • Packaging should remain sealed
  • Avoid temperature above 30C
  • Avoid storage outside and in direct sunlight
  • Use within 8 hours of opening packaging