Parts by Weight Formulation Crystic 124PA 100 Catalyst M or MEKP M-50 1 - 2.5 Curing should not be carried out at temperature below 150C and the resin must be allowed to attain workshop temperature before being formulated for use. These resins require the addition of catalyst only to start the curing reaction. The catalyst must be thoroughly stirred in the resin.
Gel Time:
The amount of catalyst and the ambient temperature control the gel time of the resin formulation. The following table shows the gel time of 100 pbw Crystic 123 or 124 containing various levels of Catalyst M.Parts of Catalyst to 100 parts of catalyzed resins 1 1.5 2 Gel time in minutes at 25°C 37.5 23.25 16.5 Gel time in minutes at 30°C 29 18 12.5
Properties
- Appearance
- Clear
- Typical Liquid Resin Properties
- Laminate properties
- Resin Properties - Unfilled Casting (Cured)
- Note
* - Made with 4 layers of 450g/m² mat
Cure 1 - 24 hours at 20°C, 16 hours at 40°C
Cure 2 - As Cure 1, then after 2 hours boil in water (tested wet)
Value | Units | Test Method / Conditions | |
Viscosity (at 25°C, spindle 3, 60 RPM) | 400 | cP | Brookfield LVF Viscometer |
Specific Gravity (at 25°C) | 1.11 | — | — |
Acid Value | 24 | mg KOH/g | — |
Volatile Content | 38 | % | — |
Value | Units | Test Method / Conditions | |
Glass Content (cure 1)* | 32 | % | — |
Tensile Strength (cure 1)* | 122 | MPa | — |
Tensile Modulus (cure 1)* | 8500 | MPa | — |
Elongation at Break (cure 1)* | 2 | % | — |
Flexural Strength (cure 1)* | 183 | MPa | — |
Flexural Modulus (cure 1)* | 6300 | MPa | — |
Glass Content (cure 2)* | 32 | % | — |
Tensile Strength (cure 2)* | 117 | MPa | — |
Tensile Modulus (cure 2)* | 8400 | MPa | — |
Elongation at Break (cure 2)* | 2 | % | — |
Flexural Strength (cure 2)* | 174 | MPa | — |
Flexural Modulus (cure 2)* | 5700 | MPa | — |
Value | Units | Test Method / Conditions | |
Barcol Hardness (Model GYZJ 934 -1) | 45 | — | — |
Water Absorption (24 h, at 23°C) | 18 | mg | — |
Deflection Temperature Under Load (1.80 MPa) | 69 | °C | — |
Specific Gravity (at 25°C) | 1.21 | — | — |
Elongation at Break (at 20°C) | 2.1 | % | — |
Tensile Strength | 65 | MPa | — |
Tensile Modulus | 3800 | MPa | — |
Regulatory & Compliance
- Quality Standards
Packaging & Availability
- Packaging Type
- Packaging Information
Crystic 124PA are supplied in 225kg steel containers.
Storage & Handling
- Storage Conditions