Crystic® Polyester Resin R115NT is a general purpose non thixotropic, non accelerated, orthophthalic, unsaturated polyester resin. It has a gel time of 10 minutes and can be used for the production of filled castings or for reinforced laminates on flat molds.

Polymer Name: Thermoset Polyester

Functions: Resins, Binders & Matrix Materials, Surface Finish

Chemical Family: Orthophthalics, Polyesters, Unsaturated Polyester (UPE)

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Features & Benefits

Materials Features
Features and Benefits
  • Low viscosity
  • Rapid hardening
  • Non accelerated
  • High filler content
  • Fast mold turn-round
  • Total control of the gel time in the workshop

Applications & Uses

Recommended Applications

CRYSTIC 115 NT can be used for the production of filled castings or for reinforced laminates on flat molds.

Formulation Guidelines

The following cold curing formulation is recommended:

  • CRYSTIC 115 NT : 100 parts
  • Catalyst M : 1 to 2 parts
  • Accelerator E : 1 to 4 parts

Catalyst M is a Méthyl Ethyl Kétone Peroxyde at 50% such as the Butanox M 50 from AKZO. Accelerator E is a cobalt octoate with 0,4% active cobalt . Catalyst and accelerator should not be mixed directly together as they will react with explosive violence.

Properties

Typical Liquid Resin Properties
ValueUnitsTest Method / Conditions
Viscosity (at 25°C, Rhéomat 37.35 s⁻¹)3.3 - 3.9dPa.s
Specific Gravity (at 25°C)1.1
Acid Index16 - 22mg KOH/g
Volatile Content38 - 42%
Gel Time (at 25°C, for 100 g of resin (+ 2g cata. M + 4g acc. E))9 - 11Minutes
Cured Properties
ValueUnitsTest Method / Conditions
Barcol Hardness (GYZJ 934-1)*50
Water Absorption (24h, at 23°C)*14mg
Heat Deflection Temperature (under load 1.8 MPa)*65°C
Specific Gravity (at 20°C)*1.2
Elongation (at break)*2%
Tensile Strength*62MPa
Tensile Modulus*3800MPa
Note

Test according to BS 2782 :1980
1MPa = 1MN/m2 = 1N/mm2 = 10,2 kgf/cm2
* cured 24 h at 20°C then 3 h à 80°C except for the HDT where the schedule was 24 h at 20°C then 5 h at 80°C then 3h at 120°C.

Technical Details & Test Data

Gel Time

The ambient temperature, the quantity and the type of catalyst will control the gel time of the resin.

Parts of catalyst M
for 100 parts of resin
accelerated with 4% acc. E
(or 0.27% of a 6% cobalt solution)
1 2
Gel time at 15°C in min. 74 28
Gel time at 20°C in min. 48 19
Gel time at 25°C in min. 30 10

Curing should not be carried out at temperature below 15°C.

Additives

Since certain pigments, fillers or extra styrene may the affect properties of CRYSTIC 115 NT their effect should be evaluated before addition to the formulation.

Post Curing

For most applications satisfactory result will be obtained by curing at room temperature (20°C). Some improvement in properties may be obtained by post-curing 16 hours at 40°C after release from the mold.

Safety & Health

Health and Safety Information

The most important protective measures to be taken with unsaturated resins and resin systems are:

  • Correct storage
  • Stock rotation
  • Adequate workplace ventilation
  • Local extraction where vapor
  • Concentrations may build up or are high
  • Use of fresh air masks in confined spaces or spray applications outside of spray booths
  • Work place monitoring of vapor concentrations
  • Good housekeeping
  • Systematic work routines
  • Competent personnel
  • Supervision, training and instruction
  • Fire precautions
  • Correct disposals
Points of Caution

Monomer and solvent vapor concentrations above certain levels can be hazardous to health and safety. The safety risks are associated essentially with the fire and possible explosions. The risks to health come mainly from the build up of vapors in the workplace in excess of certain limits and the limits applicable to the user’s country should be determined. The symptoms of the more common vapors are similar, i.e. dry irritating throat, coughing, drowsiness, and headache. Both liquids and vapors may cause skin irritation and dermatitis to susceptible personnel.

Packaging & Availability

Packaging Type
Packaging
Crystic® 115 NT is supplied in 225 kg or 1100 kg containers. Bulk supplies can be delivered by road tanker.
Variants

CRYSTIC 115 is a thixotropic and non accelerated version. Variants are available with a minimum quantity of order.

Storage & Handling

Shelf Life
9 Months
Storage
Crystic® 115 NT should be stored between 5°C and 25°C in the original, unopened container in a dry, well ventilated place. Protect from freezing and direct sunlight. Avoid contact with oxidizing agents. If stored outside of these recommendations, shelf life will be significantly reduced.