company tower banner
SHD Composites Company Logo

SHD Composites LTC216

Shanghai Sunwise Chemical LTC216 Prepreg is designed to cure at low temperatures whilst giving the potential for high temperature tooling. Typical initial cure cycles are 40 hrs at 45°C or 16 hrs at 55°C, followed by a 200°C post cure. LTC216 can be supplied on a variety of fabrics to meet your cost and manufacturing requirements.

Polymer Name: Epoxy Resins & Compounds

Functions: Prepreg

Reinforcement Material: Carbon Fibers, Glass Fibers

Processing Methods: Prepreg Processing

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Reinforcement Material
Composite Materials Functions

Features & Benefits

Labeling Claims
Key Features
  • Cure temperature from 45°C to 70°C
  • Service temperature up to 210°C after post cure
  • Low CTE and shrinkage • Work life at 20°C: 7 days
  • Storage life at -18°C: 12 months
  • Very low VOC content – no added solvents during manufacture
  • Excellent handleability in warmer conditions

Applications & Uses

Composites Processing Methods
Typical Applications

Low CTE tooling

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Cure Temperature45 - 70°C
Cure Time50 - 5hrs,mins
Outlife7months
Tg Onset218
Tg Peak242
Service Temperature210°C

Technical Details & Test Data

Cure Cycles and Performances
Temperature Duration Tg
45°C (minimum) 40 to 50 hours* 55°C
55°C 16 to 18 hours* 65°C
60°C 10 hours 70°C
70°C (maximum) 5 hours 80°C
200°C Post Cure 8 hours 220°C

*The initial cure duration will depend on part and tool geometry, volume, mass, etc.

  • Curing Schedule is meant to be a guide only and is subject to local conditions.
  • To avoid exotherm particular care must be taken with thick laminates.

           Ramp rates must not exceed 1.0°C per minute during initial cure.

           Ramp rates must not exceed 0.3°C per minute during post cure (free standing).

Safety & Health

Health And Safety

This material contains epoxy resin which can cause allergic reactions with skin contact and must avoid repeated and prolonged skin contact.

The following precautions must be taken when using epoxy resin prepregs:

  • Overalls must be worn.
  • Impervious gloves must be worn.
  • Curing schedule is meant to be as a guide only and is subject to local conditions.
  • To avoid exotherm, particular care must be taken with thick laminates.
  • Ramp rates must not exceed 1.0°C/min during initial cure and 0.3°C/min during post cure.

Packaging & Availability

Packaging Type

Storage & Handling

Storage and Out Life

This material should be kept frozen at -18°C. It must be kept sealed in a polythene bag which must not be opened until fully thawed to room temperature. If the material is not fully used, then the material must be resealed in the polythene bag to prevent moisture absorption.