US SPEC RA Grout is a blend of specialty cements and proprietary admixtures. This material is designed to provide maximum flow, shrinkage compensation and extended working times in an aggregate free formulation where clearances are minimal. RA Grout is non-metallic and non-corrosive.

Product Type: Grout

Features: High Flowability, Low Shrinkage, Non Corrosive

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Product Type

Features & Benefits

Labeling Claims
Benefits
  • Extreme fluidity : Can be pumped into areas that are virtually inaccessible with standard non-shrink grouts.
  • Working time : Extended for maximum pumping range.
  • Strength : Attains high compressive strengths at specified water ratios.
  • Thixotropic : High flow restored by agitation.
  • Corrosion Protection : Encapsulates tendons, bolts or bars to protect from corrosion.
  • Consistent : Strict Quality Control testing and standards.

Applications & Uses

Uses

RA Grout is ideal for a wide variety of applications:

  • Grouting of tight clearances between precast segments, beams, columns, fissures and cracks in rocks.
  • Anchor bolts, soil nails, rock and ground anchors, dowels and rods where sanded grouts restrict complete encapsulation.
  • Pumping applications and maximizing anchorages.
Application

Coverage/Yield:

50 lbs (22.7 kg) will fill approximately 0.53 ft³ (0.015 m³) when 7.75 quarts mixing water is used.

Mixing:

For larger batches, use a colloidal mixer. For smaller batches, use a heavy duty 1/2” (15 mm) (or larger) low-speed, corded drill and mixing paddle #6 per ICRI Technical Guideline 320.5. Pre-wet mixer and empty excess water. Place 3/4 of the required 7.75 quarts of cool, clean potable water in mixer, then add dry material. Mix on low RPM for a total of 3 to 5 minutes, adding the remaining water, until a homogenous mixture is achieved. Mix only enough grout that can be placed within working time. Do not blend excess water as this will cause bleeding and segregation. Do not use any other admixtures or additives.

Placing:

Grout should be placed using established procedures. Mechanical vibration may cause segregation. When necessary, provide vent holes. RA Grout must be 100% encapsulated to prevent cracking.

Properties

Physical Properties
Property and Test Method Results
Compressive Strength 1 Day 7 Days 28 Days
ASTM C942 per 4.4.2 4,500 psi 9,000 psi 12,000 psi
  (31.02 MPa) (62.05 MPa) (82.73 MPa)
Rate of Set Working Time Set
ASTM C953 per 4.4.1 2:30:00 AM 8:00:00 AM
Bond Strength 1 Day 7 Days 28 Days
ASTM C882 900 psi 1,600 psi 1,800 psi
  (6.20 MPa) (11.03 MPa) (12.41 MPa)
Fluidity Test Efflux Time
ASTM C939 Flow Cone <30 seconds
30 Minutes Fluidity Test Efflux Time
Following 30 Seconds of Remixing Flow Cone <30 seconds
Wick Induced Bleed Age Percent Bleed
ASTM C940 modified per 4.4.6.1 4 Hours 0%
Volume Change 1 Day 28 Days
ASTM C1090 ≥ 0.0% < 0.20%
Permeability Age Applied Voltage Charge Passed
ASTM C1202 28 Days 30 V

<2,500 coulombs

Accelerated Corrosion Test Time RA Grout
  1,000 hours No corrosion
Schupack Pressure Bleed Gelman Pressure Percent Bleed
4.4.6.2, Table 4.1(b) 30 psi < 2.0%
Inclined Tube Test Age Percent Bleeding
EN 445 per 4.4.9

Immediately after Mixing

30 min after mixing with

30 sec remix    

0.00%

0.00%

Regulatory & Compliance

Standards

RA Grout meets and exceeds the requirements of ASTM C1107 and Corp of Engineers CRD C621. When tested in accordance with ASTM C827, RA Grout yields a controlled, positive expansion.

Technical Details & Test Data

Limitations

Do not apply when the surface or ambient temperature is below 40°F (4°C) or expected to fall below 40°F (4°C) within 48 hours. When grouting at minimum temperatures, ensure surfaces in contact with grout do not fall below 40°F (4°C) until final set has been achieved and grout has reached 3,000 psi. Do not apply over surfaces that are frozen or contain frost. Do not apply over any active faults or cracks in the substrate without addressing any movement that may occur. Do not use as a patching or overlay mortar or in unconfined areas. Not recommended for heavy-duty precision grouting of machinery base plates or crane rails. Setting time will speed up in hot weather and slow in cold weather. Maintain contact areas between 40°F (4°C) and 90°F (32°C) prior to grouting and during initial curing period.

Safety & Health

Danger

This product contains Crystalline Silica (CAS# 14808-60-7) and Portland Cement (CAS# 65997-15-1). Harmful if swallowed. Causes skin irritation. Causes serious eye damage. May cause an allergic skin reaction. May cause cancer. May cause respiratory irritation. Causes damage to organs through prolonged or repeated exposure. Do not eat, drink or smoke when using this product. Wash hands thoroughly after handling. Contaminated work clothing must not be allowed out of the workplace. Do not handle until all safety precautions have been read and understood. Wear protective gloves/protective clothing/eye protection/face protection. Use only outdoors or in a well-ventilated area. Do not breathe dust. Keep away from children. Store locked up. Store in a well-ventilated place. Keep container tightly closed. Dispose of contents/container in accordance with local/regional/national/international regulations.

First Aid
  • If swallowed : Immediately call a poison center/doctor. Rinse mouth.
  • If in eyes : Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a poison center/doctor.
  • If on skin : Wash with plenty of water. Take off contaminated clothing and wash it before reuse.
  • If skin irritation or rash occurs : Get medical advice/attention.
  • If inhaled : Remove person to fresh air and keep comfortable for breathing. Call a poison center/doctor if you feel unwell.

Packaging & Availability

Packaging Type
Packaging

50 lb (22.7 kg) bag, 48 bags per pallet.

Storage & Handling

Storage

Normal cement storage and handling practices should be observed. Store in an interior, cool, dry place. Shelf life is one year in original, unopened container.