- Highly effective release performance with fluorocarbon as the principal ingredient. A thin, even film is produced, making it ideal for the release of precision components.
- PFOA and PFOS free* and complies with environmental regulations such as TSCA and RoHS. ≤5ppb detection limit.
- Little transfer, no stickiness left on the mold product.
- Minimal mold contamination is produced, reducing mold -cleaning requirements and improving productivity.
Applications & Uses
- Markets
- Compatible Polymers & Resins
- Applications
Rubbers
SBR, NBR,EPDM,FKM,CR,ACM, etc.
Thermosetting resins
Epoxy, Unsaturated polyester, Phenol, etc.
Thermoplastics
PE, PP, PVC, ABS, etc.
Properties
- Physical Form
- Appearance
- Clear liquid
- Physical Properties
- Note
The above values in properties are representative and not guaranteed.
Value | Units | Test Method / Conditions | |
Fire Service Act | Flammable | — | — |
Principal Solvent | Isooctane | — | — |
Recommendable Diluting Solvent | Petroleum solvents | — | — |
Recommendable Dilution Ratio | 1 - 10 times | — | — |
Solid Component | 3 | mass% | — |
Specific Gravity (at 25℃) | 0.74 | — | — |
Regulatory & Compliance
- Certifications & Compliance
- Chemical Inventories
Technical Details & Test Data
- Method of Use
Dilution
- Use the agent straight or dilute with recommendable solvent appropriately, and agitate ituntil uniformly mixed.
- Part of the ingredients may settles out when it is used under 15°C. In that case, gradually heat it up to around 25°C .and agitate it before use.
How to apply
- Before using the product for the first time, remove the old release agent completely. Use the steps in ‘(2) Cleaning the mold’ below to clean correctly.
- Apply a uniform coating film using an air spray device or rag.
- When spraying onto a mold, spray the mold release agent lightly with a few passes over the mold.
- It is more effective to apply a few thin coating films of low concentration of the agent than to apply a single thick coating film of high concentration.
- Be sure to use an appropriate amount of the agent since use of an excessive amount may result in mold contamination.
Cleaning the mold
- Slight contamination of the mold release agent can usually be removed to a certain degree by wiping with a solvent (IPA, toluene, acetone).
- Alkaline cleaning agents are effective for complete removal. (Immerse in an approx. 10% aqueous solution of potassium hydroxide or sodium hydroxide to which a small amount of surfactant has been added. The cleaning solution should be at a temperature of 60‐80°C)
Use temperature range
From room temperature to 300
Safety & Health
- Handling / Safety Information
- Be sure to read the Safety Data Sheet (SDS) and precautions on the label before using.