Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Technologies
- Product Families
Features & Benefits
Applications & Uses
- Markets
- Applications
- Product Applications
It is useful for general purpose casting, potting or encapsulating intricate circuits, operational amplifiers, transformers, and other electric/electronic components.
- Instruction for Use
1. To each 100 grams of Part B, add 45 grams of Part A and mix it well preferably using a mechanical mixer.
2. Vacuum degas for about 3-4 minutes to remove any dissolved or entrapped air.
3. Proceed with the casting or potting application and cure as recommended.- Instruction for Use
These materials are intended for industrial use only, and the practices of good housekeeping, safety and cleanliness should be followed before, during and after use.
Properties
- Typical Properties
- Typical Cured Properties
Value | Units | Test Method / Conditions | |
Polyol | Part B | — | — |
Isocyanate | PART A | — | — |
Mix Ratio by Volume (A:B) | 45:100 | — | — |
Mixed Viscocity (at 25°C) | 300 - 600 | cPs | — |
Pot Life (at 25°C, 100g) | 40-60 | minutes | — |
Recommended cure (at 65°C) | 2 | hours | — |
Alternate Cure (at 25°C) | 24 - 48 | hours | — |
Value | Units | Test Method / Conditions | |
Specific Gravity | 1.2 | — | — |
Hardness | 58 | Shore A | — |
Water Absorption (24 hr at Room Temperature) | 0.25 | % | — |
Weight Loss (at 120°C, 7 days) | 0.2 | % | — |
Thermal Conductivity | 0.25 | W/m °K | — |
Service Temperature Range | -55 to 120 | °C | — |
Glass Transition Temperature (Tg) | max. 10 | °C | — |
Coefficient of Thermal Expansion | 120 | ppm/°C | — |
Dielectric Strength (0.125 inch) | 420 | Volts/mil | — |
Dielectric Constant (at 1 kHz) | 4.2 | — | — |
Dissipation Factor (at 1 kHz) | 0.02 | — | — |
Volume Resistivity | 2x10^14 | Ω-cm | — |
Regulatory & Compliance
- Certifications & Compliance
Safety & Health
- Warning
Although the system contains low volatility materials, care should be taken in handling. Adequate ventilation of work place and ovens is essential. For eyes, flush immediately with plenty of water for at least 10 minutes and seek medical attention.
Storage & Handling
- Shelf Life
The shelf life of these materials is six months when stored in unopened containers at an average temperature of 25°C. If containers are opened and the contents only partially used, the container should be flushed with dry nitrogen before being resealed.
Once opened, store in 20-25°C temperatures in dry environment. Common urethanes are moisture sensitive which can lead to altered behavior and performance.