Value | Units | Test Method / Conditions | |
Tensile Modulus (dry) | 319000 | psi | ISO 527 |
Tensile Modulus (cond.) | 247000 | psi | ISO 527 |
Tensile Strength (dry) | 8270 | psi | ISO 527 |
Yield Stress (dry) | 8270 | psi | ISO 527 |
Yield Stress (cond.) | 7540 | psi | ISO 527 |
Yield Strain (dry) | 4 | % | ISO 527 |
Yield Strain (cond.) | 20 | % | ISO 527 |
Stress at 50% Strain (dry) | 6090 | psi | ISO 527 |
Stress at Break (dry) | 7110 | psi | ISO 527 |
Nominal Strain at Break (ɛtb, dry) | 190 | % | ISO 527 |
Nominal Strain at Break (ɛtb, cond.) | min. 50 | % | ISO 527 |
Charpy Notched Impact Strength (+23°C, dry) | 2.38 | ftlb/in² | ISO 179/1eA |
Charpy Notched Impact Strength (+23°C, cond.) | 4.28 | ftlb/in² | ISO 179/1eA |
Charpy Notched Impact Strength (-30°C, dry) | 2.85 | ftlb/in² | ISO 179/1eA |
Charpy Notched Impact Strength (-30°C, cond.) | 3.33 | ftlb/in² | ISO 179/1eA |
Flexural Modulus (23°C, dry) | 303000 | psi | ISO 178 |
Flexural Stress at Conv. Deflection (23°C, dry) | 9720 | psi | ISO 178 |
Flexural Strength (23°C, dry) | 11600 | psi | ISO 178 |
Flexural Strain at Flexural Strength (23°C, dry) | 6.5 | % | ISO 178 |
Value | Units | Test Method / Conditions | |
Density (dry) | 1.06 | g/cm³ | ISO 1183 |
Water Absorption (dry) | 2.7 | % | Sim. to 1SO 62 |
Humidity Absorption (dry) | 1 | % | Sim. to ISO 62 |
Value | Units | Test Method / Conditions | |
Melting Temperature (dry) | 419 | °F | ISO 11357-1/-3 |
Temperature of Deflection Under Load A (1.80 Mpa, dry) | 140 | °F | ISO 75-1/-2 |
Temperature of Deflection Under Load B (0.45 Mpa, dry) | 284 | °F | ISO 75-1/-2 |
Vicat Softening Temperature A (10 N, 50 K/h, dry) | 412 | °F | ISO 306 |
Vicat Softening Temperature B (50 N, 50 K/h, dry) | 356 | °F | ISO 306 |
Coefficient of Linear Thermal Expansion (23°C to 55 °C, Parallel, dry) | 7.22e-05 | in/in/°F | ISO 11359-1/-2 |
Coefficient of Linear Thermal Expansion (23°C to 55 °C, Normal, dry) | 6.67e-05 | in/in/°F | ISO 11359-1/-2 |
Value | Units | Test Method / Conditions | |
Volume Resistivity (pV, dry) | min. 1E13 | Ohm*m | IEC 62631-3-1 |
Relative Permittivity (100Hz, dry) | 3.8 | — | IEC 62631-2-1 |
Relative Permittivity (1MHz, dry) | 3.4 | — | IEC 62631-2-1 |
Dissipation Factor (100Hz, dry) | 260 | E-4 | IEC 62631-2-1 |
Dissipation Factor (1Mhz, dry) | 310 | E-4 | IEC 62631-2-1 |
Electric Strength (AC, S20/S20, t. 1 mm, dry.) | 711 | kV/in | IEC 60243-1 |
Electric Strength (AC, S20/P50, dry) | 711 | V/ mil | Sim. to IEC 60243-1 |
Comparative Tracking Index (Test Solution A, 50 Drops Value, dry) | 600 | — | IEC 60112 |
Value | Units | Test Method / Conditions | |
Minimum Mold Temperature | 86 | °F | — |
Maximum Mold Temperature | 212 | °F | — |
Minimum Melt Temperature | 446 | °F | — |
Maximum Melt Temperature | 518 | °F | — |
Value | Units | Test Method / Conditions | |
Injection Molding - Melt Temperature | 482 | °F | ISO 294 |
Injection Molding - Mold Temperature | 176 | °F | ISO 294 |
Injection Molding - Injection Velocity | 7.87 | in/s | ISO 294 |
Injection Molding - Pressure at Hold | 10200 | psi | ISO 294 |
Value | Units | Test Method / Conditions | |
Melt Volume Flow Rate (dry, at 527°F, 1lb)) | 70 | cm³/10min | ISO 1133 |
Melt Volume Flow Rate (dry, at 464°F, 1lb) | 59 | cm³/10min | ISO 1133 |
Molding Shrinkage (Parallel, dry) | 1.3 | % | ISO 294-4, 2577 |
Molding Shrinkage (Normal, dry) | 1.4 | % | ISO 294-4, 2577 |
Mold Temperature (dry) | 176 | °F | — |
Melt Temperature (dry) | 482 | °F | — |
Value | Units | Test Method / Conditions | |
Burning Behavior (at 1.5 mm Nominal Thickness) (dry) | HB | class | IEC 60695-11-10 |
Burning Behavior (at Thickness 0.1260 in.) (dry) | HB | class | IEC 60695-11-10 |