SABIC's Specialties Business LNP THERMOCOMP EF006 compound is based on Polyetherimide (PEI) resin containing 30% glass fiber. This product does not contain PFAS intentionally added during SHPP’s manufacturing process and are not expected to contain unintentional PFAS impurities. Each user is responsible for evaluating the presence of unintentional PFAS impurities.

Polymer Name: Polyether Imide (PEI)

Processing Methods: Injection Molding

Fillers Included: Glass Fiber

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Fillers Included
Plastics & Elastomers Functions
Technologies

Features & Benefits

Labeling Claims

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Flame Rating
Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Stress (Break) ¹¹188MPaASTM D638
Tensile Stress (Break) ¹¹177MPaISO 527
Tensile Stress (Yield, 5 mm/min) ¹¹169MPaISO 527
Tensile Strain (Break, 5 mm/min) ¹¹2%ISO 527
Tensile Strain (Break) ¹¹2.4%ASTM D638
Tensile Strain (Break) ¹¹2.2%ISO 527
Tensile Modulus (at 1 mm/min) ¹¹10350MPaISO 527
Tensile Modulus (at 50 mm/min) ¹¹11440MPaASTM D638
Flexural Stress (Yield, at 2 mm/min) ¹¹235MPaISO 178
Flexural Stress ¹¹263MPaISO 178
Flexural Stress ¹¹270MPaASTM D790
Flexural Modulus (at 2 mm/min) ¹¹9200MPaISO 178
Flexural Modulus ¹¹11370MPaASTM D790
Flexural Modulus ¹¹11510MPaISO 178
Physical Properties
ValueUnitsTest Method / Conditions
Mold Shrinkage (flow) ᵍ ¹¹0.2 - 0.4%SABIC method
Density ¹¹1.52g/cm³ISO 1183
Density ¹¹1.528g/cm³ASTM D792
Moisture Absorption (at 23°C, 50% RH, 24hrs) ¹¹0.15%ASTM D570
Mold Shrinkage (flow, 24 hrs) ᵍ ¹¹0.2%ASTM D955
Mold Shrinkage (flow, 24 hrs) ᵍ ¹¹0.23%ISO 294
Mold Shrinkage (xflow, 24 hrs) ᵍ ¹¹0.5%ASTM D955
Mold Shrinkage (xflow, 24 hrs) ᵍ ¹¹0.49%ISO 294
Wear Factor Washer ¹¹13010^-10 in^5-min/ft-lb-hrASTM D3702 Modified: Manual
Dynamic COF ¹¹0.55ASTM D3702 Modified: Manual
Static COF ¹¹0.5ASTM D3702 Modified: Manual
Moisture Absorption (at 23°C, 50% RH) ¹¹0.21%ISO 62
Thermal Properties
ValueUnitsTest Method / Conditions
Coefficient of Thermal Expansion (at 23°C to 60°C, flow) ¹¹0.0000181/°CISO 11359-2
Coefficient of Thermal Expansion (at 23°C to 60°C, xflow) ¹¹0.0000431/°CISO 11359-2
Heat Deflection Temperature/Bf (at 0.45 Mpa, Flatw 80*10*4, sp=64mm) ¹¹214°CISO 75/Bf
Heat Deflection Temperature/Af (at 1.8 Mpa, Flatw 80*10*4, sp=64mm) ¹¹209°CISO 75/Af
Relative Temperature Index (Electrical) ᵖ ¹¹105°CUL 746B
Relative Temperature Index (Mechanical with impact) ᵖ ¹¹105°CUL 746B
Relative Temperature Index (Mechanical without impact) ᵖ ¹¹105°CUL 746B
Heat Deflection Temperature (at 1.82 MPa, 3.2mm, Unannealed) ¹¹203°CASTM D648
Coefficient of Thermal Expansion (at -40°C to 40°C, flow) ¹¹0.00003061/°CASTM E831
Coefficient of Thermal Expansion (at -40°C to 40°C, flow) ¹¹0.00003091/°CISO 11359-2
Coefficient of Thermal Expansion (at -40°C to 40°C, xflow) ¹¹0.00004141/°CASTM E831
Coefficient of Thermal Expansion (at -40°C to 40°C, xflow) ¹¹0.00004161/°CISO 11359-2
Impact Properties
ValueUnitsTest Method / Conditions
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹45kJ/m²ISO 180/1U
Izod Impact (Notched, 80*10*4, at 23°C) ¹¹10kJ/m²ISO 180/1A
Izod Impact (Unnotched, at 23°C) ¹¹758J/mASTM D4812
Izod Impact (Notched, at 23°C) ¹¹106J/mASTM D256
Instrumented Dart Impact Energy (Peak, at 23°C) ¹¹12JASTM D3763
Multi-Axial Impact ¹¹2JISO 6603
Injection Molding
ValueUnitsTest Method / Conditions
Drying Temperature ⁷150°C
Drying Time ⁷4 - 6Hrs
Maximum Moisture Content ⁷0.02%
Melt Temperature ⁷360 - 400°C
Rear - Zone 1 Temperature ⁷360 - 380°C
Middle - Zone 2 Temperature ⁷370 - 390°C
Front - Zone 3 Temperature ⁷380 - 400°C
Nozzle Temperature ⁷390 - 400°C
Mold Temperature ⁷140 - 180°C
Back Pressure ⁷0.3 - 0.7MPa
Screw Speed (Circumferential speed) ⁷0.2 - 0.3m/s
Vent Depth ⁷0.025 - 0.076mm
Flame Characteristics
ValueUnitsTest Method / Conditions
UL Recognized (94V-0 Flame Class Rating) ᵖmin. 0.75mmUL 94
Note
  • ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
  • ᵖ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card.
  • ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
  • ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
 

Regulatory & Compliance

Certifications & Compliance

Packaging & Availability

Country Availability
Regional Availability
  • Americas
  • Europe
  • North America