SABIC's Specialties Business LNP™ THERMOCOMP™ LF008EX1 compound is based on Polyetheretherketone (PEEK) resin containing 40% glass fiber. Added features of this grade include: High Modulus and Strength, Easy Molding and Low Warpage.

Polymer Name: Polyetheretherketone (PEEK)

Processing Methods: Injection Molding

Fillers Included: Glass Fiber

Flexural Modulus: 12700.0 - 12700.0 MPa

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Fillers Included
Plastics & Elastomers Functions
Technologies

Features & Benefits

Applications & Uses

Plastics & Elastomers Processing Methods
Potential Applications

PEEK based LNP THERMOCOMP compound may be qualified to use in industrial, oil & gas applications for combination of high heat, chemical resistance and mechanical performance.

Properties

Mechanical Properties
ValueUnitsTest Method / Conditions
Flexural Strength (at 1.3 mm/min, 50 mm span) ¹¹260MPaASTM D790
Flexural Modulus (at 1.3 mm/min, 50 mm span) ¹¹12300MPaASTM D790
Tensile Stress (Break, Type I, 5 mm/min) ¹¹190MPaASTM D638
Tensile Modulus (at 5 mm/min) ¹¹14000MPaASTM D638
Tensile Strain (Break, Type I, 5 mm/min) ¹¹2.2%ASTM D638
Flexural Strength (at 2 mm/min) ¹¹265MPaISO 178
Flexural Modulus (at 2 mm/min) ¹¹12700MPaISO 178
Tensile Stress (Break, 5 mm/min) ¹¹193MPaISO 527
Tensile Modulus (at 1 mm/min) ¹¹13800MPaISO 527
Tensile Strain (Break, 5 mm/min) ¹¹2%ISO 527
Physical Properties
ValueUnitsTest Method / Conditions
Specific Gravity ¹¹1.62ASTM D792
Mold Shrinkage (flow, 24 hrs) ᵍ ¹¹0.2 - 0.3%ASTM D955
Mold Shrinkage (xflow, 24 hrs) ᵍ ¹¹0.4 - 0.5%ASTM D955
Density ¹¹1.61g/cm³ASTM D792
Moisture Absorption (at 23°C, 50% RH) ¹¹0.04%ISO 62
Thermal Properties
ValueUnitsTest Method / Conditions
Relative Temperature Index (Electrical) ¹¹130°CUL 746B
Relative Temperature Index (Mechanical with impact) ¹¹130°CUL 746B
Relative Temperature Index (Mechanical without impact) ¹¹130°CUL 746B
Heat Deflection Temperature (at 1.82 MPa, 3.2mm, Unannealed) ¹¹315°CASTM D648
Heat Deflection Temperature (at 0.45 MPa, 3.2 mm, Unannealed) ¹¹337°CASTM D648
Heat Deflection Temperature/Af (at 1.8 Mpa, Flatw 80*10*4, sp=64mm) ¹¹310°CISO 75/Af
Heat Deflection Temperature/Bf (at 0.45 Mpa, Flatw 80*10*4, sp=64mm) ¹¹336°CISO 75/Bf
Coefficient of Thermal Expansion (at -40°C to 120°C, flow) ¹¹0.0000191/°CASTM E831
Coefficient of Thermal Expansion (at -40°C to 120°C, xflow) ¹¹0.0000371/°CASTM E831
Electrical Properties
ValueUnitsTest Method / Conditions
Dielectric Constant (at 1.1 GHz) ¹¹4.02SABIC method
Dissipation Factor (at 1.1 GHz) ¹¹0.0042SABIC method
Dielectric Constant (at 1.9 GHz) ¹¹4.03SABIC method
Dissipation Factor (at 1.9 GHz) ¹¹0.0045SABIC method
Impact Properties
ValueUnitsTest Method / Conditions
Izod Impact (Notched, at 23°C) ¹¹134J/mASTM D256
Izod Impact (Unnotched, at 23°C) ¹¹873J/mASTM D4812
Izod Impact (Notched, 80*10*4, at 23°C) ¹¹12kJ/m²ISO 180/1A
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹58kJ/m²ISO 180/1U
Charpy Impact (at 23°C, V-notch Edgew 80*10*4 sp=62mm) ¹¹12kJ/m²ISO 179/1eA
Charpy Impact (at 23°C, Unnotch Edgew 80*10*4 sp=62mm) ¹¹60kJ/m²ISO 179/1eU
Multi-Axial Impact ¹¹20JASTM D3763
Injection Molding
ValueUnitsTest Method / Conditions
Drying Temperature ⁷120 - 150°C
Drying Time ⁷3 - 5Hrs
Nozzle Temperature ⁷380 - 400°C
Melt Temperature ⁷380 - 400°C
Front - Zone 3 Temperature ⁷370 - 380°C
Middle - Zone 2 Temperature ⁷360 - 370°C
Rear - Zone 1 Temperature ⁷290 - 300°C
Mold Temperature ⁷170 - 200°C
Screw Speed ⁷50 - 100rpm
Flame Characteristics
ValueUnitsTest Method / Conditions
UL Recognized (94-5VA Flame Class Rating)3mmUL 94
UL Recognized (94-5VB Flame Class Rating)1.5mmUL 94
UL Recognized (94V-0 Flame Class Rating)0.75mmUL 94
Note
  • ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
  • ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
  • ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
 

Packaging & Availability

Regional Availability
  • Americas
  • Asia
  • Europe
  • North America