SABIC's Specialties Business LNP THERMOCOMP UX06032 compound is based on Polyphthalamide (PPA) resin containing 30% glass fiber. Added features of this grade include: Non-Brominated & Non-Chlorinated Flame Retardant, Heat Stabilized. This product does not contain PFAS intentionally added during SHPP’s manufacturing process and are not expected to contain unintentional PFAS impurities. Each user is responsible for evaluating the presence of unintentional PFAS impurities.

Polymer Name: Polyphthalamide (PPA)

Processing Methods: Injection Molding

Fillers Included: Glass Fiber

Additives Included: Flame Retardant, Heat Stabilizer

Flexural Modulus: 9900.0 - 9900.0 MPa

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Fillers Included
Plastics & Elastomers Functions
Technologies

Features & Benefits

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Flame Rating
Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Stress (Break, 5 mm/min) ¹¹130MPaISO 527
Tensile Strain (Break, 5 mm/min) ¹¹2.1%ISO 527
Tensile Modulus (at 1 mm/min) ¹¹1.14E+04MPaISO 527
Flexural Stress (Break, 2 mm/min) ¹¹200MPaISO 178
Flexural Modulus (at 2 mm/min) ¹¹9900MPaISO 178
Physical Properties
ValueUnitsTest Method / Conditions
Mold Shrinkage (on Tensile Bar, flow) ᵍ ¹¹0.2 - 0.3%SABIC method
Density ¹¹1.46g/cm³ISO 1183
Water Absorption (at 23°C, 24hrs) ¹¹0.23%ISO 62-1
Thermal Properties
ValueUnitsTest Method / Conditions
Coefficient of Thermal Expansion (at 23°C to 60°C, flow) ¹¹0.0000211/°CISO 11359-2
Coefficient of Thermal Expansion (at 23°C to 60°C, xflow) ¹¹0.0000541/°CISO 11359-2
Heat Deflection Temperature/Bf (at 0.45 Mpa, Flatw 80*10*4, sp=64mm) ¹¹275°CISO 75/Bf
Heat Deflection Temperature/Af (at 1.8 Mpa, Flatw 80*10*4, sp=64mm) ¹¹258°CISO 75/Af
Relative Temperature Index (Electrical) ᵖ ¹¹140°CUL 746B
Relative Temperature Index (Mechanical with impact) ᵖ ¹¹140°CUL 746B
Relative Temperature Index (Mechanical without impact) ᵖ ¹¹140°CUL 746B
Electrical Properties
ValueUnitsTest Method / Conditions
Volume Resistivity ¹¹1000000000000000 - 100000000000000000Ω.cmASTM D257
Comparative Tracking Index ʳ ¹¹600VIEC 60112
Comparative Tracking Index (UL, PLC) ¹¹0PLC CodeUL 746A
Hot Wire Ignition (PLC 0) ¹¹min. 0.41mmUL 746A
High Ampere Arc Ignition (PLC 0) ¹¹min. 0.41mmUL 746A
Impact Properties
ValueUnitsTest Method / Conditions
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹40kJ/m²ISO 180/1U
Izod Impact (Notched, 80*10*4, at 23°C) ¹¹5kJ/m²ISO 180/1A
Injection Molding
ValueUnitsTest Method / Conditions
Drying Temperature ⁷120 - 140°C
Drying Time ⁷4 - 6Hrs
Melt Temperature ⁷305 - 315°C
Front - Zone 3 Temperature ⁷295 - 315°C
Middle - Zone 2 Temperature ⁷290 - 310°C
Rear - Zone 1 Temperature ⁷280 - 300°C
Mold Temperature ⁷130 - 150°C
Back Pressure ⁷0.2 - 0.3MPa
Screw Speed ⁷40 - 80rpm
Flame Characteristics
ValueUnitsTest Method / Conditions
UL Recognized (94V-0 Flame Class Rating) ¹⁷min. 0.41mmUL 94
Glow Wire Ignitability Temperature (at 0.8 mm) ¹⁷825°CIEC 60695-2-13
Glow Wire Ignitability Temperature (at 1.6 mm) ¹⁷825°CIEC 60695-2-13
Glow Wire Ignitability Temperature (at 3.0 mm) ¹⁷850°CIEC 60695-2-13
Glow Wire Flammability Index (at 3 mm) ¹⁷960°CIEC 60695-2-12
Glow Wire Flammability Index (at 0.8 mm) ¹⁷960°CIEC 60695-2-12
Glow Wire Flammability Index (at 1.6 mm) ¹⁷960°CIEC 60695-2-12
Note
  • ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
  • ᵖ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card.
  • ʳ UL Ratings shown on the technical datasheet might not cover the full range of thicknesses, colors and regions. For details, please see the UL Yellow Card.
  • ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
  • ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
  • ¹⁷ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card. The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
 

Regulatory & Compliance

Certifications & Compliance

Packaging & Availability

Regional Availability
  • Americas
  • Asia
  • Europe
  • North America