Knowde Enhanced TDS
Identification & Functionality
- Additives Included
- Fillers Included
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
Applications & Uses
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
Properties
- Flame Rating
- Mechanical Properties
- Physical Properties
- Thermal Properties
- Electrical Properties
- Impact Properties
- Injection Molding
- Flame Characteristics
- Note
- ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
- ᵖ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card.
- ʳ UL Ratings shown on the technical datasheet might not cover the full range of thicknesses, colors and regions. For details, please see the UL Yellow Card.
- ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
- ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
Value | Units | Test Method / Conditions | |
Taber Abrasion (CS-17, 1 kg) ¹¹ | 60 | mg/1000cy | SABIC method |
Tensile Stress (Yield, Type I, 5 mm/min) ¹¹ | 100 | MPa | ASTM D638 |
Tensile Stress (Yield, 5 mm/min) ¹¹ | 90 | MPa | ISO 527 |
Tensile Stress (Yield, 5 mm/min) ¹¹ | 80 | MPa | ISO 527 |
Tensile Stress (Yield, Type I, 10 mm/min) ¹¹ | 88 | MPa | SABIC - Japan Method |
Tensile Strain (Break, Type I, 5 mm/min) ¹¹ | 3 | % | ASTM D638 |
Tensile Stress (Break, 5 mm/min) ¹¹ | 80 | MPa | ISO 527 |
Tensile Strain (Yield, 5 mm/min) ¹¹ | 2.5 | % | ISO 527 |
Tensile Strain (Yield, Type I, 10 mm/min) ¹¹ | 6 - 8 | % | SABIC - Japan Method |
Tensile Modulus (at 5 mm/min) ¹¹ | 6500 | MPa | ASTM D638 |
Tensile Strain (Break, 5 mm/min) ¹¹ | 2.5 | % | ISO 527 |
Tensile Strain (Break, 5 mm/min) ¹¹ | 3 | % | ISO 527 |
Flexural Stress (Yield, 2.6 mm/min, 100 mm span) ¹¹ | 131 | MPa | ASTM D790 |
Tensile Modulus (at 1 mm/min) ¹¹ | 6000 | MPa | ISO 527 |
Flexural Modulus (at 2.6 mm/min, 100 mm span) ¹¹ | 5570 | MPa | ASTM D790 |
Flexural Stress (Break, 2 mm/min) ¹¹ | 120 | MPa | ISO 178 |
Flexural Modulus (at 2 mm/min) ¹¹ | 5400 | MPa | ISO 178 |
Flexural Modulus (at 2 mm/min) ¹¹ | 4500 | MPa | ISO 178 |
Ball Indentation Hardness (H358/30) ¹¹ | 100 | MPa | ISO 2039-1 |
Flexural Stress (Yield, at 2 mm/min) ¹¹ | 150 | MPa | ISO 178 |
Value | Units | Test Method / Conditions | |
Mold Shrinkage (on Tensile Bar, flow) ᵍ ¹¹ | 0.2 - 0.4 | % | SABIC method |
Specific Gravity ¹¹ | 1.23 | — | ASTM D792 |
Density ¹¹ | 1.25 | g/cm³ | ISO 1183 |
Water Absorption (at 23°C, 24hrs) ¹¹ | 0.12 | % | ISO 62-1 |
Water Absorption (at 23°C, 24hrs) ¹¹ | 0.06 | % | ASTM D570 |
Mold Shrinkage (flow) ᵍ ¹¹ | 0.2 - 0.4 | % | SABIC method |
Water Absorption (at 23°C, saturated) ¹¹ | 0.2 | % | ISO 62-1 |
Melt Flow Rate (at 300°C, 5.0 kgf) ¹¹ | 11.7 | g/10 min | ASTM D1238 |
Moisture Absorption (at 23°C, 50% RH) ¹¹ | 0.04 | % | ISO 62 |
Moisture Absorption (at 23°C, 50% RH) ¹¹ | 0.06 | % | ISO 62 |
Melt Volume Rate (at 280°C, 10.0 kg) ¹¹ | 15 | cm³/10 min | ISO 1133 |
Melt Volume Rate (at 280°C, 5.0 kg) ¹¹ | 2 | cm³/10 min | ISO 1133 |
Value | Units | Test Method / Conditions | |
Thermal Conductivity ¹¹ | 0.26 | W/m-°C | ISO 8302 |
Coefficient of Thermal Expansion (at 23°C to 80°C, flow) ¹¹ | 0.00003 | 1/°C | ISO 11359-2 |
Coefficient of Thermal Expansion (at 23°C to 80°C, xflow) ¹¹ | 0.00007 | 1/°C | ISO 11359-2 |
Vicat Softening Temperature (Rate A/50) ¹¹ | 145 | °C | ISO 306 |
Vicat Softening Temperature (Rate B/50) ¹¹ | 140 | °C | ISO 306 |
Vicat Softening Temperature (Rate B/50) ¹¹ | 135 | °C | ISO 306 |
Heat Deflection Temperature (at 1.82 MPa, 3.2mm, Unannealed) ¹¹ | 137 | °C | ASTM D648 |
Vicat Softening Temperature (Rate B/120) ¹¹ | 140 | °C | ISO 306 |
Vicat Softening Temperature (Rate B/120) ¹¹ | 147 | °C | ISO 306 |
Heat Deflection Temperature (at 1.82 MPa, 6.4 mm, Unannealed) ¹¹ | 138 | °C | ASTM D648 |
Heat Deflection Temperature/Be (at 0.45MPa, Edgew 120*10*4, sp=100mm) ¹¹ | 130 | °C | ISO 75/Be |
Coefficient of Thermal Expansion (at -30°C to 30°C) ¹¹ | 0.000028 - 0.000045 | 1/°C | TMA |
Heat Deflection Temperature/Ae (at 1.8 Mpa, Edgew 120*10*4, sp=100mm) ¹¹ | 120 | °C | ISO 75/Ae |
Relative Temperature Index (Electrical) ᵖ ¹¹ | 90 | °C | UL 746B |
Relative Temperature Index (Electrical) ᵖ ¹¹ | 65 | °C | UL 746B |
Relative Temperature Index (Mechanical with impact) ᵖ ¹¹ | 90 | °C | UL 746B |
Relative Temperature Index (Mechanical with impact) ᵖ ¹¹ | 65 | °C | UL 746B |
Heat Deflection Temperature/Af (at 1.8 Mpa, Flatw 80*10*4, sp=64mm) ¹¹ | 135 | °C | ISO 75/Af |
Relative Temperature Index (Mechanical without impact) ᵖ ¹¹ | 90 | °C | UL 746B |
Relative Temperature Index (Mechanical without impact) ᵖ ¹¹ | 65 | °C | UL 746B |
Value | Units | Test Method / Conditions | |
Comparative Tracking Index (UL, PLC) ¹¹ | 4 | PLC Code | UL 746A |
High Ampere Arc Ignition (PLC 4) ¹¹ | min. 1.5 | mm | UL 746A |
Hot Wire Ignition (PLC 1) ¹¹ | min. 1.5 | mm | UL 746A |
Hot Wire Ignition (PLC 2) ¹¹ | min. 3 | mm | UL 746A |
High Voltage Arc Track Rate (PLC) ¹¹ | 4 | PLC Code | UL 746A |
Arc Resistance (Tungsten, PLC) ¹¹ | 6 | PLC Code | ASTM D495 |
Volume Resistivity ¹¹ | 1.00E+15 | Ω.cm | IEC 60093 |
Surface Resistivity (ROA) ¹¹ | min. 1.E+15 | Ω | IEC 60093 |
Dielectric Strength (in oil, at 3.2mm) ¹¹ | 18 | kV/mm | IEC 60243-1 |
Relative Permittivity (1 MHz) ¹¹ | 2.9 | — | IEC 60250 |
Dissipation Factor (at 50/60 Hz) ¹¹ | 0.0008 | — | IEC 60250 |
Dissipation Factor (at at 1 MHz) ¹¹ | 0.003 | — | IEC 60250 |
Comparative Tracking Index ʳ ¹¹ | 250 | V | IEC 60112 |
Relative Permittivity (50/60 Hz) ¹¹ | 2.9 | — | IEC 60250 |
Value | Units | Test Method / Conditions | |
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹ | 23 | kJ/m² | ISO 180/1U |
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹ | 30 | kJ/m² | ISO 180/1U |
Izod Impact (Unnotched, 80*10*4, at -30°C) ¹¹ | 23 | kJ/m² | ISO 180/1U |
Charpy Impact (at 23°C, Unnotch Edgew 80*10*4 sp=62mm) ¹¹ | 25 | kJ/m² | ISO 179/1eU |
Charpy Impact (at -30°C, Unnotch Edgew 80*10*4 sp=62mm) ¹¹ | 25 | kJ/m² | ISO 179/1eU |
Izod Impact (Unnotched, at 23°C) ¹¹ | 550 | J/m | ASTM D4812 |
Izod Impact (Notched, at 23°C) ¹¹ | 88 | J/m | ASTM D256 |
Instrumented Dart Impact Total Energy (at 23°C) ¹¹ | 20 | J | ASTM D3763 |
Izod Impact (Notched, 80*10*4, at 23°C) ¹¹ | 10 | kJ/m² | ISO 180/1A |
Izod Impact (Notched, 80*10*4, at -30°C) ¹¹ | 9 | kJ/m² | ISO 180/1A |
Charpy Impact (at 23°C, V-notch Edgew 80*10*4 sp=62mm) ¹¹ | 8 | kJ/m² | ISO 179/1eA |
Value | Units | Test Method / Conditions | |
Drying Temperature ⁷ | 100 - 120 | °C | — |
Drying Temperature ⁷ | 110 - 120 | °C | — |
Drying Time ⁷ | 3 - 4 | Hrs | — |
Drying Time ⁷ | 2 - 3 | Hrs | — |
Drying Time (Cumulative) ⁷ | 8 | Hrs | — |
Melt Temperature ⁷ | 280 - 300 | °C | — |
Melt Temperature ⁷ | 300 - 325 | °C | — |
Maximum Moisture Content ⁷ | 0.02 | % | — |
Nozzle Temperature ⁷ | 260 - 280 | °C | — |
Nozzle Temperature ⁷ | 300 - 325 | °C | — |
Front - Zone 3 Temperature ⁷ | 280 - 300 | °C | — |
Front - Zone 3 Temperature ⁷ | 290 - 325 | °C | — |
Middle - Zone 2 Temperature ⁷ | 260 - 280 | °C | — |
Middle - Zone 2 Temperature ⁷ | 275 - 320 | °C | — |
Rear - Zone 1 Temperature ⁷ | 240 - 260 | °C | — |
Rear - Zone 1 Temperature ⁷ | 265 - 315 | °C | — |
Hopper Temperature ⁷ | 60 - 80 | °C | — |
Mold Temperature ⁷ | 80 - 110 | °C | — |
Mold Temperature ⁷ | 80 - 120 | °C | — |
Back Pressure ⁷ | 0.3 - 0.7 | MPa | — |
Screw Speed ⁷ | 20 - 100 | rpm | — |
Shot to Cylinder Size ⁷ | 30 - 70 | % | — |
Value | Units | Test Method / Conditions | |
UL Recognized (94HB Flame Class Rating) ʳ | min. 1.5 | mm | UL 94 |
UL Recognized (94HB Flame Class Rating) ʳ | 1.5 | mm | UL 94 |
UV-light (Water exposure/immersion) ʳ | F1 | — | UL 746C |
Glow Wire Flammability Index (passes at 750°C) ʳ | 3.2 | mm | IEC 60695-2-12 |
Oxygen Index (LOI) ʳ | 26 | % | ISO 4589 |
Regulatory & Compliance
- Certifications & Compliance
Packaging & Availability
- Country Availability
- Regional Availability