Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Fillers Included
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
Features & Benefits
- Labeling Claims
Applications & Uses
- Applications
Properties
- Flame Rating
- Flame Rating
- IEC 60695-11-10 V0
- Mechanical Properties
- Physical Properties
- Thermal Properties
Value | Units | Test Method / Conditions | |
Elongation Modulus | 8300 | MPa | ISO 527-1 |
Breaking Stress | 95 | MPa | ISO 527-1 |
Elongation at Break | 2 | % | ASTM D 638 |
Charpy Impact Strength (23°C) | 35 | kJ/m2 | ISO 179/1eU |
Charpy Notched Impact Strength (23°C) | 6 | kJ/m2 | ISO 179/1eA |
Value | Units | Test Method / Conditions | |
Shrinkage - Flow | 0.3 | % | ISO 294-4 |
Shrinkage - Across Flow | 1 | % | ISO 294-4 |
Moisture Absorption (23°C/50%) | 0.3 | % | ISO 62 |
Density | 1510 | kg/m3 | ASTM D 792 |
Value | Units | Test Method / Conditions | |
Melting Point - DSC (10°C/min) | 225 | °C | ISO 11357-1/-3 |
Heat Deflection Temperature - HDT (1.80 MPa) | 195 | °C | ISO 75-1/-2 |
Heat Deflection Temperature - HDT (0.45 MPa) | 215 | °C | ISO 75/2 B f |
Fire Behavior (0.8 mm Wall Thickness) | V-0 | - | IEC 60695-11-10 |