PPS-GF40, cross-linked PPS, 40% glass fiber reinforced, hydrolysis stabilized

Polymer Name: Polyphenylene Sulfide (PPS)

Fillers Included: Glass Fiber

Technical Data Sheet

Similar Products

  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Fillers Included
Plastics & Elastomers Functions
Technologies

Features & Benefits

Applications & Uses

Plastics & Elastomers End Uses

Properties

Flame Rating
Flame Rating
IEC 60695-11-10 V0
Mechanical Properties
ValueUnitsTest Method / Conditions
Elongation Modulus14500MPaISO 527-1
Breaking Stress185MPaISO 527-1
Elongation at Break1.6%ASTM D 638
Charpy Impact Strength (23°C)43kJ/m2ISO 179/1eU
Charpy Notched Impact Strength (23°C)10kJ/m2ISO 179/1eA
Physical Properties
ValueUnitsTest Method / Conditions
Melt Index - MFR (300°C/5 kg)17g/10minISO 1133
Density1650kg/m3ASTM D 792
Water Absorption0.02%ISO 62
Thermal Properties
ValueUnitsTest Method / Conditions
Melting Point - DSC (10°C/min)280°CISO 11357-1/-3
Heat Deflection Temperature - HDT (1.80 MPa)260°CISO 75-1/-2
Coefficient of Thermal Expansion - Flow230.000001/KISO 11359-1/-2
Coefficient of Thermal Expansion - Across Flow31E-6/KISO 11359-1/-2
Fire Behavior (0.4 mm Wall Thickness)V-0-IEC 60695-11-10
Fire Behavior (0.8 mm Wall Thickness)V-0-IEC 60695-11-10
Electrical Properties
ValueUnitsTest Method / Conditions
Volume Resistance100000000000000.0ohm.mIEC 60093