Knowde Enhanced TDS
Identification & Functionality
- Product Type
- Technologies
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Performance Benefits
- Superior Rust Protection
- Very versatile product. Can be used in immersion or spray applications.
- Does not foam and tends to float oil.
- Does not contain free caustic.
- Can be used in ambient applications
- Hard water stable.
- Does not contain any Sara 313 listed components.
Applications & Uses
- Markets
- Application Method
- Recommended Applications
Concentration Temperature Range
Spray / Flood 5% to 10% Ambient to 170°F
Immersion 5% to 10% Ambient to 170°F
Ultrasonic 5% to 10% Ambient to 170°F
Vibratory 3% to 6% Ambient to 170°F
Parts coming out of the washer should be blown off using hot air though suitable for multi-metal cleaning, we recommend that yellow metals and some aluminum alloys be rinsed with clean water to remove any residual alkaline residues.
Properties
- Physical Form
- Appearance
- Clear (of Dilution), Light amber liquid (Concentrate)
- Odor
- Mild
- Characteristics
Value | Units | Test Method / Conditions | |
pH (Typical Operating Range) | 10.0 | — | — |
Density (at 15°C) | 8.2 | lbs/gal | — |
Nitrites | No | — | — |
Silicates | No | — | — |
Phenols | No | — | — |
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Concentration Control
Titration Method:
- Titration Factor : 0.257
- Accurately measure 100mL or the in-use fluid into a flask
- Titrate to pH of 4.6 with 0.5N HCl
- Concentration = mL of 0.5N HCl X Titration Factor
mL of 0.5N HCl % Concentration
19.5 5 23.3 6 27.2 7 31.1 8
Dropper Method:
- Dropper Factor : 0.178
- Measure10mL of the in-use cleaner into a small flask using a 5mL disposable syringe.
- Add 2-4 drops of Bromphenol Blue indicator to the cleaner, swirl to mix. Sample should turn a dark blue.
- Add 1.0N HCl dropwise to until sample turns yellow
- Concentration = Drops of 1.0N HCl X Dropper Factor
Drops of 1.0N HCl % Concentration
39 7 45 8 50 9 56 10
Concentration measurement using a refractometer is not recommended.
- Titration Factor : 0.257