Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
Features & Benefits
- Materials Features
Applications & Uses
- Markets
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
- Hot Charged Air Ducts Application Data
Details
Akulon® PA6 is used for temperature up to 150-180˚C.Benefits
- Stanyl® PA46, Stanyl® Diablo PA46, Akulon® Diablo PA and Arnitel® HT TPC allow for light weight solutions as compared to metal or rubber or alternative plastics (Stanyl® is 10% lighter than PPS)
- Stanyl® PA46, Stanyl® Diablo PA46, Akulon® Diablo PA and Arnitel® HT TPC allow for cost effective solutions (Stanyl lowers system cost up to 20% versus metal)
- Stanyl® PA46, Stanyl® Diablo PA46, Akulon® Diablo PA and Arnitel® HT TPC allow for reliable solutions (Stanyl® Diablo is long term resistant up to 230 ˚C, Akulon® Diablo ca be used around 200 ˚C) and Arnitel® HT is ideal as single part solution for flexible hot charge ducts.
- Clean Air Inlet Ducts Application Data
Details
Blow molding grades and injection molding grades are available. For even higher temperatures Diablo grades are available.Benefits
- Arnitel® TPC allows for light weight solutions (50% lighter than rubber)
- Arnitel® TPC allows for reliable solutions due to its perfect combination of high (aging) temperature resistance and good flexibility and chemical resistance
- Akulon® PA6 allows for light weight solutions (50% lighter than metal) and for more rigid duct solutions.
Properties
- Mechanical Properties
- Thermal Properties
- Other Properties
- Mechanical Properties (Die Cutting)
- Mechanical Properties (TPE)
- Rheological Properties
Value | Units | Test Method / Conditions | |
Nominal Strain at Break | >50 | % | ISO 527-1/-2 |
Value | Units | Test Method / Conditions | |
Melting Temperature (10°C/min) | 202 | °C | ISO 11357-1/-3 |
Glass Transition Temperature from DMTA (tan d) | -12 | °C | ASTM D5026/D7028 |
Value | Units | Test Method / Conditions | |
Density | 1240 | kg/m³ | ISO 1183 |
Value | Units | Test Method / Conditions | |
Stress at Break (normal) | 67 | MPa | ISO 527-1/-2 |
Stress at 5% strain (normal) | 9 | MPa | ISO 527-1/-2 |
Stress at 10% strain (normal) | 12 | MPa | ISO 527-1/-2 |
Stress at 50% strain (normal) | 16 | MPa | ISO 527-1/-2 |
Stress at 100% strain (normal) | 18 | MPa | ISO 527-1/-2 |
Strain at Break (normal) | 592 | % | ISO 527-1/-2 |
Value | Units | Test Method / Conditions | |
Tensile Modulus | 145 | MPa | ISO 527-1/-2 |
Stress at 5% strain | 7 | MPa | ISO 527-1/-2 |
Stress at 10% strain | 11 | MPa | ISO 527-1/-2 |
Stress at 50% strain | 17 | MPa | ISO 527-1/-2 |
Stress at 100% strain | 21 | MPa | ISO 527-1/-2 |
Stress at Break | 32 | MPa | ISO 527-1/-2 |
Nominal Strain at Break | 237 | % | ISO 527-1/-2 |
Shore D Hardness (3s) | 52 | — | ISO 868 |
Value | Units | Test Method / Conditions | |
Melt Flow Index (at 230 °C, 10 kg) | 15 | g/10min | ISO 1133 |
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Chemical Resistance
Chemical Type Chemical Name Resistance Other Acetic acid (10% by mass) at 23°C resistant Ketones Acetone at 23°C resistant Other Ammonium hydroxide (10% by mass) at 23°C limited resistant, tests necessary to verify Other ASTM 1 at 23°C resistant Other ASTM 3 at 23°C resistant Other Brake fluids (DOT 3/4) at 23°C not resistant Other Calcium chloride (10% by mass) at 23°C limited resistant, tests necessary to verify Other Chloroform at 23°C not resistant Ethers Diethyl ether at 23°C limited resistant, tests necessary to verify Alcohols Ethanol at 23°C limited resistant, tests necessary to verify Other Ethyl Acetate at 23°C limited resistant, tests necessary to verify Other Fuel; Diesel at 85°C resistant Other Hydrochloric acid (10% by mass) at 23°C resistant Other Hydrogen peroxide (30% by mass) at 23°C limited resistant, tests necessary to verify Other Nitric acid (10% by mass) at 23°C resistant Other Phosphoric acid (10% by mass) at 23°C resistant Other Sodium hydroxide (10% by mass) at 23°C resistant Other Sulfuric acid (30% by mass) at 23°C resistant Other Tetrachloroethylene at 23°C limited resistant, tests necessary to verify Hydrocarbons Toluene at 23°C resistant Other Transformer oil at 23°C not resistant Other Trichloroethylene at 23°C not resistant Other Water at 23°C resistant Other Zinc chloride (10% by mass) at 23°C resistant - Dynamic Shear Modulus (G)-Temperature
- Stress-Strain (TPE)
Packaging & Availability
- Packaging Type